Detecto icon Owner's Manual

Detecto icon Owner's Manual

Digital clinical scale
Hide thumbs Also See for icon:

Advertisement

icon
Digital Clinical Scale
Owner's Manual
3300-0192-0M Rev D 01/17
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the icon and is the answer not in the manual?

Questions and answers

Summary of Contents for Detecto icon

  • Page 1 Digital Clinical Scale Owner’s Manual 3300-0192-0M Rev D 01/17...
  • Page 2 3300-0192-0M Rev D 01/17...
  • Page 3 INTRODUCTION ® Thank you for purchasing our Detecto icon Digital Clinical Scale. It has been manufactured with quality and reliability at our factory in Webb City, MO USA. Your scale has been tested before leaving our factory to insure accuracy and dependability for years to come.
  • Page 4 PROPER DISPOSAL When this device reaches the end of its useful life, it must be properly disposed of. It must not be disposed of as unsorted municipal waste. Within the European Union, this device should be returned to the distributor from where it was purchased for proper disposal. This is in accordance with EU Directive 2002/96/EC.
  • Page 5: Table Of Contents

    Height Rod – Detecto Sonar Height Rod ....... .
  • Page 7: Specifications

    SPECIFICATIONS Capacity: 600 lb x 0.2 lb / 1,000 lb x 0.5 lb 300 kg x 0.1 kg / 500 kg x 0.2 kg Weighing/Height Units: Pounds/Inch (lb, in) or Kilograms/Centimeters (kg, cm) Platform Size: 17 in W x 17 in D x 1.5 in H (43 cm W x 43 cm D x 3.8 cm D) Overall Dimensions: 17 in W x 18.5 in D x 88.5 in H...
  • Page 8 This page intentionally left blank. 3300-0192-0M Rev D 01/17...
  • Page 9: Site Preparation Requirements

    Electrical Power The icon Digital Clinical Scale has been designed to operate from a 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA listed AC power adapter. Note that a special order is not required for operation at 230 VAC.
  • Page 10: Unpacking

    UNPACKING Carefully remove the icon Digital Clinical Scale from the shipping carton and inspect it for any damage that may have taken place during shipment. Keep and use the original carton and packing material for return shipment if it should become necessary. The purchaser is responsible for filing all claims for any damages or loss incurred during transit.
  • Page 11 Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Step 10 Step 11 Step 12 3300-0192-0M Rev D 01/17...
  • Page 12: Placing The Scale

    NiMH. DO NOT mix Alkaline and Ni-Cad or NiMH batteries. NOTE: The icon scale does not have a battery charging circuit. Should you wish to use Ni-Cad or NiMH batteries, they must be fully charged before installing. When discharged, Ni-Cad or NiMH batteries must be removed and placed in an external charger to recharge.
  • Page 13: Battery Status

    Battery Status The battery status will be displayed when batteries are installed. A number will be displayed in the upper right of the screen indicating the level of charge remaining in the batteries. For example 100 = 100% charge, 75 = 75% charge, etc. When the batteries are the point they need to be replaced (Alkaline) or recharged (NiCad or NiMH) and the battery voltage drops too low for accurate weighing, the scale will automatically shut off and you will be unable to turn it back on.
  • Page 14: Units Selection

    LB/IN or KG/CM. 1. Press key to turn the scale on. 2. The scale display will show the software version for a few seconds, the Detecto logo briefly and then change to the Select Units screen. Select Units...
  • Page 15: Keypad Functions

    KEYPAD FUNCTIONS DO NOT operate the keys or touchscreen with pointed objects (pencils, pens, etc.). Damage to keys or touchscreen resulting from this practice is NOT covered under warranty. This is the Power key. With the scale off, pressing this key will apply power to it and turn on the display.
  • Page 16 This is the Menu key. Press and release this key to launch the Menu screen. The first screen that is displayed is the Setup Review screen where you can see all of the settings at a glance. To continue into setup, touch the Setup key at the bottom right of the touch screen.
  • Page 17: Annunciators

    ANNUNCIATORS The annunciators are displayed on the Weight screen to show that the scale is in the mode corresponding to the annunciator label or that the status indicated by the label is active. Weight Mode WEIGHT: POUNDS/GROSS Power Status Status CENTER ZERO Messages (AC or ##)
  • Page 18: Operation

    OPERATION ALWAYS assist the patient in stepping on and off the scale platform to ensure they do not fall. NEVER leave a patient unattended while they are on the scale platform. Failure to maintain control of the patient at all times can result in serious injury to you and/or the patient.
  • Page 19: Body Mass Index (Bmi) Operation - (No Id)

    Body Mass Index (BMI) Operation – (No ID) To Weight, Measure Height and Calculate BMI 1. Press key to turn scale on. 2. If required, press 0 key to zero weight screen. 3. Assist patient onto scale. NOTE: In order to obtain an accurate height measurement, instruct patient to look straight ahead and not down at scale display.
  • Page 20: Body Mass Index (Bmi) Operation Manually Entering Known Height

    Body Mass Index (BMI) Operation Manually Entering Known Height 1. Press key to turn scale on. 2. If required, press 0 key to zero weight screen. 3. Press HEIGHT on display screen. 4. If POUNDS/INCHES was selected for Units: in setup, display will change to show HEIGHT IN INCHES on screen.
  • Page 21: Scale Setup

    SCALE SETUP Your icon Digital Clinical Scale has been pre-configured at the factory and should not require changes for use in most applications. However, if the factory settings do not meet the requirements of your operation, the following describes the setup process for your scale.
  • Page 22 Setup Menu Page 1 MENU PAGE 1 Cal=16, Cfg=30 Units: lb, in Auto Locking: 7 sec. Sonar Ht: 223.3 cm <<< Exit >>> Cal=XX, Cfg=YY – Audit Trail Counters These are the Audit Trail Counters for the number of times that the metrological and non- metrological settings have been changed.
  • Page 23 Setup Menu Page 2 MENU PAGE 2 Capacity1: 600.0 Capacity2: 1000.0 Interval1: 2 Interval2: 5 <<< Exit >>> Capacity1: Touching this key will open the capacity screen. This will allow you to set the capacity of the first range. Using the numeric keys, enter a new value and then press the Save key to save it.
  • Page 24 Setup Menu Page 3 MENU PAGE 3 Decimal1: 1 Decimal2: 1 Motion Range: 3 Filter Mode: 0 <<< Exit >>> Decimal1: Touching this key will open the decimal entry screen. This will allow you to set the decimal point precision for the first weight range. Using the numeric keys, enter a new value and then press the Save key to save it.
  • Page 25 Setup Menu Page 4 MENU PAGE 4 Zero Tracking: 10 Power up Zero: Yes Gravity: 1.000000 OIML: No <<< Exit >>> Zero Tracking: Touching this key will open the zero tracking screen. This will allow you to set the number of half (1/2) divisions that the scale will attempt to maintain zero.
  • Page 26 Exit Model: This will change the default settings and operation of the scale. For instance, select “Icon” as the model in order to use the stand-up type scale with the sonar height measurement. For wheelchair type scales with tare functionality, select “Wheelchair” as the model.
  • Page 27: Scale Calibration

    SCALE CALIBRATION To Enter Calibration Setup 1. Enter the Setup menu of the scale by pressing the Menu key. 2. Enter in the desired setup parameters for the scale. 3. Select Calibrate Scale from the Setup Menu Page 5. 4. Make certain the scale platform is empty and free of debris. 5.
  • Page 28 This page intentionally left blank. 3300-0192-0M Rev D 01/17...
  • Page 29: Error And Operation Messages

    ERROR AND OPERATION MESSAGES The icon scale is equipped with diagnostic software that tests various portions of the scale's circuitry and verifies proper operation. Should a problem be detected, an error or status message will be displayed. The following lists these messages and their meaning.
  • Page 30: Before You Call Service

    BEFORE YOU CALL FOR SERVICE Problem Possible Solutions Display does not turn on AC Operation:  Is AC power supply fully inserted into wall receptacle?  Check wall receptacle for proper AC power. Try another electrical appliance in same receptacle, does it work? ...
  • Page 31: Care And Cleaning

    CARE AND CLEANING NOTE: The scale contains no user-serviceable parts and maintenance should be limited to an occasional cleaning and battery replacement as required.  Do not submerge the scale in water, pour or spray water directly on it to clean. The scale is not waterproof and covering it with water will damage it and void the warranty.
  • Page 32: Parts Identification

    Qty. Part Number Description 3300-0140-0A SUB-ASSY, SONAR HR 3300-0141-0A SUB-ASSY, ICON COLUMN 3300-0144-0A SUB ASSY, ICON BASE SONAR BRACKET 3300-0265-08 SCW FLAT-HEAD THREAD CUTTING TYPE 25, 6021-1293 #4-24 X 1/4, PHIL. DR. Z-PLATE 6021-6016 SCW PAN-HEAD,, SHEET METAL #6X.50 3300-0151-0A SUB-ASSY, DISPLAY, ICON ...
  • Page 33 3300-0022-08 HEIGHT SENSOR TUBE 3300-0060-08 SONAR FRONT ENCLOSURE 3300-0061-08 SONAR REAR ENCLOSURE 3300-0135-0A CABLE, ICON/APEX SONAR SCW FLAT-HEAD THREAD CUTTING TYPE 25, 6021-1293 #4-24 X 1/4, PHIL. DR. Z-PLATE SCW PAN HEAD PHILIPS #1-32X3/8” THREAD 6021-2078 FORMING, 18-8 SS 6600-0756...
  • Page 34 PARTS IDENTIFICATION Column Sub-Assembly Item Qty. Part Number Description 3300-0067-08 THROAT REAR 3300-0068-08 THROAT FRONT 3300-0087-08 COLUMN, DRILLED & SONAR 3300-0278-1A CABLE, APEX COLUMN, SONAR SCW FLAT-HEAD THREAD CUTTING TYPE 25, 6021-1293 #4-24 X 1/4, PHIL. DR. Z-PLATE 6021-1509 SCW PAN-HEAD, SHEET METAL #8X.75 6650-1114 O-RING 2 ID X 2-3/16 OD X 3/32 THK 6710-1021...
  • Page 35 Item Qty. Part Number Description 3300-0002-0A PCB ASS’Y 855 DISPLAY 3300-0050-08 DISPLAY ENCLOSURE 3300-0051-08 DISPLAY FRONT, ICON 3300-0071-08 ICON BUTTONS 3300-0090-08 UNDERLAY FOAM, ICON SCW FLAT-HEAD THREAD CUTTING TYPE 25, 6021-1293 #4-24 X 1/4, PHIL. DR. Z-PLATE 6024-0142 WASHER FLAT .250 OD, 0.093 THK NYLON...
  • Page 36 SOCKET COVER, ICON 3300-0088-08 ICON COVER PLATE 3300-0130-1A ICON ANALOG CABLE 3300-0137-0A CABLE, ICON BATTERY 3300-0147-1A SUB-ASSY, PLATFORM COVER, ICON 3300-0266-08 COLUMN CONNECTOR BRACKET, ICON 6013-0049 NUT 1/4-20 HEX JAM NUT #10-32 HEX Z/P 6013-0295 6013-2008 NUT 1/4-20 CAGE Z/P 6021-0654 SCW PAN-HEAD,, MACHINE-SCW 06-32X.250...
  • Page 37 PARTS IDENTIFICATION Base Sub-Assembly [SH1][SH2] 3300-0192-0M Rev D 01/17...
  • Page 38: Statement Of Limited Warranty

    (2) years from date of shipment. Detecto shall be the sole judge of what constitutes a defect.
  • Page 39 This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of the product. Detecto will not be liable for consequential damages of any nature, including but not limited to, loss of profit, delays or expenses, whether based on tort or contract.
  • Page 40 PO Box 151, Webb City, MO 64870 Telephone: 417-673-4631 FAX: 417-673-5001 Technical Support: 866-254-8261 Printed in USA E-mail: tech@cardet.com 3300-0192-0M Rev D 01/17 3300-0192-0M Rev D 01/17...

Table of Contents