Configuration Switches
Side View of Typical Switches
Rocker Switch
Open
Open
Datalinks
The remote I/O communications module contains three DIP switches
SW1, SW2, and SW3 (Figure 1.1 and Figure 1.2). Switches are set
On or Off as detailed in Figure 1.4. For a detailed explanation of
switch configuration, refer to Chapter 2, Installation.
Figure 1.4
Configuration Switch
OPEN
8
7
6
5
4
Slide Switch
Open
Open (Off)
Open
Closed (On)
Datalinks are a SCANport mechanism for transferring additional
information between a programmable controller and a SCANport
device. Each datalink switch on the adapter reserves two words of
the programmable controller I/O image table. The 1305, 1336
PLUS, and 1336 FORCE drives support this mechanism. For
additional details, refer to Chapter 3, Configuration and Interfacing.
3
2
1
Switch Designation as
shown in this manual
Overview
1–5
OFF (OPEN)
ON
Publication 1203–5.1 –– July, 1997