Section 10. Electrical
10.8 Crew Alerting System Messages
Message
BATTERY POWER ONLY
L AFT BUS VOLTAGE LOW
R AFT BUS VOLTAGE LOW
L FWD BUS VOLTAGE LOW
R FWD BUS VOLTAGE LOW
L (R) GEN OFFLINE
BUS TIE FAIL
LOAD SHED SYS FAULT
START BATT DISCHARGE
SYS BATT CONTACT TRIP
SYS BATT DISCHARGE
BATT BUS VOLTAGE LOW
ECB CTRL FAULT
START BATT CONTACT TRIP
BATT HEATER FAIL
238
Table 31. Electrical CAS Messages
Condition
Aircraft is operating on battery power only
Left aft bus voltage is low
Right aft bus voltage is low
Left forward bus voltage is low
Right forward bus voltage is low
Engine running, generator switched ON but no
current flow, or Generator switch off
The bus tie contactor is stuck closed
Air conditioning load shed capability is lost
(ground only)
Start Battery is discharging
Battery Bus Contactor has tripped due to over
current. System Battery is off and isolated from
Battery Bus
System Battery is discharging
Voltage on Battery Bus is low
Control of one or more ECBs has been lost or
cannot be switched off (On ground only)
Start battery contactor has tripped due to over
current. Start Battery is isolated from electrical
power system
Battery heater blanket has failed (ground only)
Copyright © — Eclipse Aviation Corporation
Eclipse 5OO Systems Manual
Category
Warning
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Caution
Advisory
Advisory
Advisory
Advisory
Version 2.0 April 2007