Section 9. Climate Control
AIR SOURCE SWITCH
OFF
NORM
L
R
NOTE:
Should AIR SOURCE switch fail an AIR SOURCE SW FAULT advisory message
appears.
CABIN DUMP SWITCH
OFF
ON
9.4.2 Pressurization Display
188
Table 21. Air Source Switch Selections
No bleed air flow. Left and right flow control valve closed.
Bleed air provided from the right and left engines at the low flow
setting. Air from the left engine flows to the cabin, while air from the
right engine flows to the cockpit.
Bleed air provided from left engine only. Right flow control valve
closed. Left flow control valve set to high flow.
Bleed air provided from right engine only. Left flow control valve
closed. Right flow control valve set to high flow. (Based on AIR
DISTR selection.)
Table 22. Cabin Dump Switch Selections
Normal operation
Both outflow valves fully open
Both flow control valves switch to high flow
All bleed air routed to cockpit
Figure 121. MFD Pressurization Display
Copyright © — Eclipse Aviation Corporation
Eclipse 5OO Systems Manual
Version 2.0 April 2007