Section 6. Ice Protection

6.7.5 Probe and/or Port Heat Failure

A complete failure of a probe or static port heat causes a L (R) PITOT HEAT FAIL, L
(R) STATIC HEAT FAIL, or STBY PITOT HEAT FAIL caution message to appear,
along with the associated caution alert tone. The failure is also indicated on the ICE
protection synoptic by the probe or port turning amber. Since static ports have two
heating elements, it is possible that only one may fail. Should this occur a L (R)
STATIC HEAT FAIL advisory message appears to alert the loss of redundancy.
108
Figure 73. Pitot/AOA Probe Failure
Copyright © — Eclipse Aviation Corporation
Eclipse 5OO Systems Manual