Section 6. Ice Protection

6.7.7 Pressure Regulating Shut-Off Valve Fault

A failure of a pressure regulating shut off valve causes a L (R) ENG A/ICE VLV
FAULT to appear. This valve fails open allowing pneumatic de-ice to remain
available.
6.7.8 De-ice Pressure Sensor Fault
Should a wing de-ice pressure sensor malfunction be detected on the ground, a
WING DEICE MON FAULT advisory message appears and flight into icing conditions
is prohibited. Should this fault occur in flight, wing de-ice is unavailable and a WING
DEICE FAIL caution appears.

6.7.9 Engine Anti-Ice Sensor Fault

Should an engine anti-ice sensor malfunction be detected on the ground, an ENG
ANTI-ICE MON FAULT advisory message appears and flight into icing conditions is
prohibited. Should this fault occur in flight, engine anti-ice is unavailable and a WING
DEICE FAIL caution appears.

6.7.10 Static Heater Monitor Fault

Should the ACS be unable to monitor the function of the static heaters, a STATIC
HTR MON FLT advisory message appears. The heaters will still operate.