FB1100/FB1200 Flow Computer Sensor Assembly Field Replacement Guide
D301842X012
November 2020
Integral Sensor

Calibration Certificate

Not Required
Required
Example Model Number:
Stainless Steel Sensor and Coplanar Flange, No Sensor Material Certificates Required, and Calibration Certificate
Required.
Table 2. FB1200 Sensor Assembly Part Numbers (Use Selection Column to Generate UL-listed Kit Number)
Integral Sensor
Differential Pressure Range & Accuracy
25 Inches H2O (62.3 mbar) DP, 0.1% Accuracy
Notes:
0.1% Accuracy is not available on Traditional Flange.
25" DP option is available only with static pressure
options G4 or A4 and the maximum pressure is limited
to 2000 psi.
Available only with stainless steel sensor & coplanar
flange.
250 Inches H2O (623 mbar) DP, 0.1% Accuracy
Note: 0.1% Accuracy is not available on Traditional Flange.
250 Inches H2O (623 mbar) DP, 0.075% Accuracy
1000 Inches H2O (2.5 bar) DP, 0.1% Accuracy
Notes:
0.1% Accuracy is not available on Traditional Flange.
1000" DP range with 0.1% accuracy available only with
Stainless steel sensor and coplanar flange.
1000" DP range not available with 300 psi static
pressure.
1000 Inches H2O (2.5 bar) DP, 0.075% Accuracy
Note : 1000" DP range not available with 300 psi static
pressure.
No Differential Pressure Required, Static Pressure only
accuracy 0.1%
Note: Available only with inline sensor option (2K11)
No Differential Pressure Required, Static Pressure only,
accuracy 0.075%
Note: Available only with inline sensor option (2K11)
Static Pressure Range - for use with Multivariable Sensor (B22* or B12* above)
MV 300 psi gauge (20.7 barg)
Note: 1000" DP range not available with 300 psi static
pressure.
MV 300 psi absolute (20.7 bara)
Note: 1000" DP range not available with 300 psi static
pressure.
MV 1500 psi gauge (103.4 barg)
iv
B222G72E12Q0RM4
= 250 Inches H2O (623 mbar) DP, 0.1% Accuracy, MV 1500 psi gauge,
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Approvals
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Selection
M0
M4
Selection
B221
B222
B122
B223
B123
B2
B1
G6
A6
G7