FB1100/FB1200 Flow Computer Sensor Assembly Field Replacement Guide
D301842X012
November 2020
31.
32.
33.
34.
12
Tighten the screws that you loosened in step12. Torque screws to 4 to 6 in-lbs (0.5 to 0.7
N m).
Take the battery pack enclosure/HMI module assembly you removed in step 8. Being
careful to keep the battery wire and its connector free, carefully slide the assembly into
the front of the housing so that the HMI module mates with the green and yellow
connector from the CPU module. Tighten the screws you loosened in step 6 to hold the
assembly in place. Torque screws to 4 to 6 in-lbs (0.5 to 0.7 N m).
Tighten the bottom screws of the HMI module you loosened in step 7 with a torque of 4 to
6 in-lbs (0.5 to 0.7 N m).
You can now proceed to rewire all connections (I/O, communications, grounding) to the
flow computer. Please refer to the instruction manual for wiring installation instructions.