Emerson FB1100 Field Replacement Manual page 3

Flow computer sensor assembly

Advertisement

Table 1. FB1100 Sensor Assembly Part Numbers (Use Selection Column to Generate UL-listed Kit Number)
Integral Sensor
Differential Pressure Range & Accuracy
25 Inches H2O (62.3 mbar) DP, 0.1% Accuracy
Notes:
0.1% Accuracy is not available on Traditional Flange.
25" DP option is available only with static pressure options G4
or A4 and the maximum pressure is limited to 2000 psi.
Available only with stainless steel sensor & coplanar flange.
250 Inches H2O (623 mbar) DP, 0.1% Accuracy
Note: 0.1% Accuracy is not available on Traditional Flange.
250 Inches H2O (623 mbar) DP, 0.075% Accuracy
1000 Inches H2O (2.5 bar) DP, 0.1% Accuracy
:
Notes
0.1% Accuracy is not available on Traditional Flange.
1000" DP range with 0.1% accuracy available only with
Stainless steel sensor and coplanar flange.
1000" DP range not available with 300 psi static pressure.
1000 Inches H2O (2.5 bar) DP, 0.075% Accuracy
Note: 1000" DP range not available with 300 psi static pressure.
Static Pressure Range - for use with Multivariable Sensor (B22* or B12* above)
MV 300 psi gauge (20.7 barg)
Note: 1000" DP range not available with 300 psi static pressure.
MV 300 psi absolute (20.7 bara)
Note: 1000" DP range not available with 300 psi static pressure.
MV 1500 psi gauge (103.4 barg)
MV 1500 psi absolute (103.4 bara)
MV 3600 psi gauge (250 barg)
Note: When used with 25" DP option, maximum working pressure
is 2000 psi/137.9 Bar.
MV 3600 psi absolute (250 bara)
Note: When used with 25" DP option, maximum working pressure
is 2000 psi/137.9 Bar.
Sensor Material & Flange Type
Stainless Steel Sensor and Coplanar Flange
Hastelloy Diaphragm and Hastelloy Coplanar Flange
Note: Not available with a 1000" 0.1% accuracy sensor or a 25"
sensor.
Stainless Steel Sensor and Traditional Flange
Note: 0.1% Accuracy is not available on Traditional Flange.
Sensor Material Certificates
Not Required
3.1 B Traceability certs to EN 10205
NACE MRO 175/ISO 15156 requires Hastelloy Diaphragm
Option
Note: Available only with 3E13.
NACE MRO 103 - requires Hastelloy Diaphragm Option
Note: Available only with 3E13.
FB1100/FB1200 Flow Computer Sensor Assembly Field Replacement Guide
Approvals
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
Class 1 Div 2 UL, IEC Ex N, ATEX Ex N
Class 1 Div 1 UL, IEC Ex d, ATEX Ex d
D301842X012
November 2020
Selection
B221
B222
B122
B223
B123
G6
A6
G7
A7
G4
A4
2E12
3E13
2F12
Q0R
Q8R
Q15R
Q25R
iii