2/ Connecting The Heated Towel Rail - Atlantic TIMELIS Installation And Operating Manual

Towel rail electronic radiator
Hide thumbs Also See for TIMELIS:
Table of Contents

Advertisement

Available languages

Available languages

2/ Connecting the device
- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using the 3-wire cable factory fitte to the heater , through a
connecting box. In damp premises, such as bathrooms and kitchens, install the connecting box at least
25cm from the ground..
- The installation must comply with local national regulation. If in doubt, ask the national Atlantic dis-
tributor.
- Ground connection is forbidden.
Do not connect the pilot wire (black) to ground.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified elec-
trician using special tools.
- If a heater pilots or is piloted by a 30mA differential (e.g. bathroom), the pilot wire supply must be pro-
tected on this differential.
3) Programming
The device can be controlled remotely if its pilot wire is connected to a device fitted with a program-
mer, a programming unit or an energy management unit.
Chart indicating the orders the device can receive over
Mode
COMFORT
achieved
Ref/neutral
oscilloscope
Measurement
between the
0 Volt
control cable
and neutral
Panel heater cable
Live=brown
Neutral=blue
Pilot wire=Black
Two possible cases
1st case: only one heater
2nd case: multiple heaters
its pilot wire
(to be measured between the pilot wire and the neutral).
ECO
230 Volts
LIVE
Electricity
grid
NEUTRAL
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
220-240V insulated cable
2
STOP HEA-
TING
STANDBY
LOAD SHED-
DING
-115 Volts
+115 Volts
negative
positive
16
COMFORT
COMFORT
-1°C
-2°C
5'
5'
7''
3''
230 Volts
230 volts
for 3 sec
for 7 sec

Advertisement

Table of Contents
loading