Connecting The Panel Heater - Atlantic Solius Eco Domo Manual

Table of Contents

Advertisement

Available languages

Available languages

CONNECTING THE PANEL HEATER

Connection rules and regulations
- The panel heater must be supplied with 230V single-phase current at 50Hz.
- The panel heater's power supply must be directly connected to the main supply after the circuit brea-
ker without any intermediate switch.
- The panel heater's power cable must be connected to the main supply via a connection box. In damp
areas, such as bathrooms and kitchens, the connection box must be installed at least 25cm above the
floor.
- An Earth connection is prohibited. Do not connect the pilot wire (black wire) to Earth.
- The installation must be fitted with an all-pole cut-off switch with a contact opening distance of at least
3mm.
- If the power cable is damaged, it must only be replaced by an electrician.
- If you are using the pilot wire and it is protected by a 30mA differential (e.g.: bathroom use), the pilot
wire's power supply must also be protected on this differential.
Wiring diagram for the heating panel
-
Cut off the power supply and connect the wires as shown in the following diagram:
- You can connect the pilot wire if your home is equipped with a programming unit or controller.
In this case, make the following checks according the selected mode (Comfort, Eco, etc.) to that the
programming instructions are being transmitted correctly:
COMFORT
SIGNAL TO BE
TRANSMITTED
MEASUREMENT
BETWEEN THE
0 Volt
PILOT WIRE
AND NEUTRAL
Panel heater cable
Phase=brown
PHASE
NEUTRAL
Neutral=blue
Pilot wire=Black
Three possible cases
The pilot wire end is insulated
1st case: only one heater
and not further connected
To the appliance with cassette or
2nd case: Slave heater
programming unit.
To pilot wire of an electronically
3rd case: Master heater
controlled appliance
ECO
FROST
SWITCH-OFF
OF HEATING
AND POWER
-115 Volts
230 Volts
negative
25
Electricity
grid
COMFORT
-1°C
CUT-OFF
5'
3''
+115 Volts
230 Volts
positive
for 3 s
GB
COMFORT
-2°C
5'
7''
230 volts
for 7 s

Advertisement