BraunAbility Simple Stow Infloor Service Manual page 17

Dodge ramp wheelchair accessible vehicle
Table of Contents

Advertisement

FUNCTION
SYMPTOM
4.10
Faulty
4.00
Operation
DOOR
(CLOSE)
4.20
Door Does Not
Close Fully
5.10
5.00
No Power to
NO
Conversion
POWER
Systems
(Circuit
Problem)
6.00
6.10
No
BACKUP
Operation
ALARM
7.10
No Interlock
Operation
7.00
PARK
INTERLOCK
7.20
Can't Shift
Out of Park
POSSIBLE CAUSE
4.11 See 1.10
4.21 See 1.10
4.22 Ramp obstructing door
5.11 Poor ground connection
5.12 Battery terminals dirty
5.13 Battery damaged
5.14 Battery discharged
5.15 12 volt source (check fuses for
12 volts)
6.11 See 5.00
6.12 Faulty alarm
6.13 Backup alarm harness
disconnected or damaged
7.11 See 5.00
7.12 Park interlock (door jamb)
switch harness disconnected
or damaged
7.13 Park interlock (door jamb)
switch out of adjustment or
damaged
7.21 Door not closed
7.22 See 7.12 and 7.13
Troubleshooting
REMEDY
Check ramp stow hold catch, correct
as needed
Clean and tighten
Clean and tighten
Replace
Charge battery
Check for blown fuse, loose termi-
nals or broken wire or cable
Replace alarm
Connect, repair or replace
Connect, repair or replace
Adjust or replace
Close door