GENERAL INFORMATION INSTALLATION SKILL REQUIREMENTS Thank you for purchasing your Low Pressure Sewer The installation of a basin system is a specialized skill, Basin System. which requires individuals with the basic understanding of excavating, pipe fitting, and electrical wiring. These instructions are meant only to be an installation guide;...
Page 3
anti-flotation tie-down kit is used. If basin is fiberglass, as material varies upon geographical location. This inspect basin and seal off any cuts or scratches to material is commonly known as "pea gravel". prevent fiberglass deterioration. B. Stone or gravel crushings with angular particle size of not less than 1/8"...
Preoperational Grinder Pump Checks: valve sealing flange aligns and connects properly with discharge. Step 1: Ensure power source is off or disconnected and remove pump from basin. Junction Box Systems: Step 2: With power off, turn radial cutter with a Step 1: Ensure power source is off or disconnected screwdriver to be sure it rotates freely.
Page 5
Refer to Local Codes! 4" to 6" FINAL BACKFILL FOR BASIN SYSTEMS Bedding (Concrete Pad or Aggregate) Polyethylene Fiberglass Backfill 4" to 6" Backfill 4" to 6" 3" 3" 12" 12" Inlet Inlet Discharge Discharge Backfill Backfill Antiflotation Flange Concrete Ballast Anchor Bolts Refer to Local Codes! (Antiflotation...
Page 6
CONDITION PROBABLE CAUSE 1. Floats are not hanging free in the basin or are covered Basin Level Is Pumped Down With "H-O-A" On Switch with grease. Pump the level down with the "H-O-A" Hand Position, But Is Not Pumped Down With "H-O-A" switch on "HAND", so that the floats can be observed.
Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility.