6.4 Pumped liquids

CAUTION
Chemical hazard
Minor or moderate personal injury
Do not use the pump for flammable liquids, such as
diesel or gasoline.
WARNING
Biological hazard
Death or serious personal injury
In domestic hot water systems, the temperature of the
pumped liquid must always be above 122 °F (50 °C)
due to the risk of legionella.
WARNING
Biological hazard
Death or serious personal injury
In domestic hot water systems, the pump is
permanently connected to the main water supply.
Therefore, do not connect the pump by a hose.
WARNING
Hot water
Death or serious personal injury
If the hot water temperature is too high, it can cause
severe burns or scalding.
Ensure that the temperature of the hot water source is
not high enough to cause burns or scalding.
CAUTION
Corrosive substance
Minor or moderate personal injury
Do not use the pump for aggressive liquids such as
acids or seawater.
The pump is suited for domestic hot water.
Maximum hardness
Maximum potable water
temperature
For water with a higher degree of hardness, contact Grundfos.
14 °dH
140 °F (60 °C)

6.5 Identification

6.5.1 Nameplate
3
1
Prod. No. XXXXXXXX
Min
CSA ENC 2
Amp
Watt
2
1 Ph 115V 60Hz
Max water temp 140 °F
6
5
Nameplate
Pos.
Description
1
Product number
2
Voltage [V]
Rated current [A]:
3
Min.: Minimum current [A]
Max.: Maximum current [A]
Input power [W]:
4
Min.: Minimum power [W]
Max.: Maximum power [W]
5
Maximum liquid temperature [°F]
6
FCC and IC ID

6.6 Approvals for ALPHA 15-55 HWR-T

Approval marks
FCC sections
Section 15.19 (a) 3
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Section 15.21
Any changes or modifications to this equipment not expressly
approved by the party responsible for compliance could void the
user's authority to operate this equipment.
4
Max
Nonsubmersible Pump
Electronically Protected Class F
WATER QUALITY
Drinking water system component
NSF/ANSI 61
NSF/ANSI 372
9