9.2.2 RECORDS

A record of testing and repairs must be maintained from the time the nozzle is purchased until it is discarded. Each TFT nozzle is
engraved with a unique serial number which, if so desired, can be used to identify nozzle for documentation purposes.
The following information, if applicable, must be included on the test record for each nozzle:
1. Assigned identifi cation number
2. Manufacturer
3. Product or model designation
4. Vendor
5. Warranty
6. Hose connection size
7. Maximum operating pressure
8. Flow rate or range
9. Date received and date put in service
10. Date of each service test and service test results
11. Damage and repairs, including who
NFPA 1962: Standard for the care, use, inspection, service testing, and replacement of fi re hose, couplings, nozzles and fi re hose appliances. (2013 ed., Section 5.3).
Quincy, MA: National Fire Protection Agency.

9.3 REPAIR

Factory service is available with repair time seldom exceeding one day in our facility. Factory-serviced nozzles are repaired by
experienced technicians to original specifi cations, fully wet tested, and promptly returned. Repair charges for non-warranty items are
minimal. Any returns should include a note as to the nature of the problem and whom to reach in case of questions.
Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability
for damage to equipment or injury to personnel that is a result of user service. Contact the factory or visit the web site at www.tft.com
for parts lists, exploded views, test procedures and troubleshooting guides.
Performance tests shall be conducted on each nozzle after a repair, or anytime a problem is reported to verify operation in accordance
with TFT test procedures. Consult factory for the procedure that corresponds to the model and serial number of the nozzle. Any
equipment which fails the related test criteria should be removed from service immediately. Troubleshooting guides are available with
each test procedure or, equipment can be returned to the factory for service and testing.
Any alterations to the PRODUCT NAME and its markings could diminish safety and constitutes a
CAUTION
misuse of this product.
For additional information on care, maintenance and testing, refer to: NFPA 1962: Standard for the Care, Use, Inspection, Service
Testing, and Replacement of Fire Hose, Couplings, Nozzles, and Fire Hose Appliances, 2013 Edition

10.0 ANSWERS TO YOUR QUESTIONS

We appreciate the opportunity of serving you and making your job easier. If you have any problems or questions, our toll-free
"Hydraulics Hotline", 800-348-2686, is normally available to you 24 hours a day, 7 days a week.
©Copyright Task Force Tips, Inc. 2015
15
LIM-045 September 15, 2015 Rev00

Advertisement

Table of Contents
loading

Table of Contents