3.4 Chimneys and flue pipes
The fireplace can be connected to a chimney and flue
pipe approved for solid fuel fired appliances with flue gas
temperatures specified in «2.0 Technical data.
The chimney's cross-section must be at least as big as the
flue pipe's cross-section. See «2.0 Technical data» when
calculating the correct chimney cross-section.
Several solid fuel fired appliances can be connected to the
same chimney if the chimney's cross-section is sufficient.
Connection to the chimney must be carried out in accordance with
the installation instructions from the supplier of the chimney.
Before making a hole in the chimney the fireplace should be
test-mounted in order to correctly mark the position of the
fireplace and the hole in the chimney. See fig. 1 for minimum
dimensions.
Ensure that the flue pipe is inclined all the way up to the
chimney.
Use a flue pipe bend with a sweeping hatch that allows it to
be swept.
Be aware of the fact that it is particularly important that
connections have a certain flexibility in order to prevent
movement in the installation leading to cracks. N.B. A correct and
sealed connection is very important for the proper functioning
of the product.
Chimney draught; See «2.0 Technical data». If the draught is
too strong you can install and operate a flue damper to control
the draught.
3.5 Assembly prior to installation
N.B. Check that the fireplace is free of any damage prior to
commencing installation.
The product is heavy! Make sure you have assistance when
erecting and installing the fireplace.
The standard product is delivered in two packing cases. One
containing the fireplace itself and one containing optional
legs, short/long or pedestal.
Once you have unpacked the product, remove the fire grate
and the heat shield.
Lift off the top plate and the air grid and bowl.
Lift off the rear heat shield (cast iron). This hangs on 3 screws,
two above and one below. See fig. 9A.
Check that the product does not have any visible damage
and that the operating handles work.
Unfold the cardboard packing and place the wooden pallet
on top. Carefully place the fireplace on its back.
Attaching the legs
1. Unscrew the screws that are screwed in the corners of the
fireplace, and attach the legs to the screws as fig. 2A shows.
2. Attach the stiffener between the rear legs - see fig. 3A.
3. The floor shall be protected from heat from the product using the
supplied heat shield. Attach it to the 4 screws as shown in fig. 4.
4. Make sure to have assistance and lift the product carefully up.
5. Adjust the product with the aid of the 4 adjusting screws in
each corner (see fig. 3B).
6. Re-attach the rear heat shield (cast iron) by first hanging it
on the top screws. Lift it up slightly and then lower it onto
the lower screw.
7. Replace the top plate with the air grid and bowl.
18
Attaching the column
1.
The pedestal consists of 4 parts, the pedestal foot, 2 pedestal
parts and an air chamber.
2.
Screw the pedestal sections together using 2 bolts M8 x 25
and 2 bolts M6 x 25, as shown in fig. 5A.
3.
Screw the pedestal to the foot plate using 4 bolts (M8 x 25),
see fig. 5B-6B.
Turn plate
If the turn plate shall be mounted, this shall be done now before
the base plate is attached to the fireplace. See the installation
instructions that are included with the turn plate.
4. Attach the pedestal to the fireplace's base plate using 4 bolts
(M8 x 20), see fig. 5C. The seams on the pedestal shall face
the sides of the product and the opening for outdoor air shall
face backwards (see: «Fresh air supply through the base»).
5. Make sure to have assistance and lift the product carefully up.
6 Adjust the product with the aid of the 4 adjusting screws in
each corner (see fig. 6A).
7. Re-attach the rear heat shield (cast iron) by first hanging it
on the top screws. Lift it up slightly and then lower it onto
the lower screw.
8. Place the top plate in position with the air grid and bowl.
Supply of outdoor air
With the F 270 it is possible to have outdoor air directly in the
product through the base, or through the flexible supply tube
from the exterior/chimney and to the connecting pipe on the
product.
Fresh air supply through the base
Mark where the product will stand, and make a hole in the
floor for insertion of tube from outdoor air.
Punch out the opening in the back of the pedestal
inside (fig. 5A), and mount the air channel as fig.7A shows.
Fresh air supply direct from the exterior or from the chimney
with air vents.
Attach a flexible tube Ø 100 mm directly to the fireplace's
connecting pipe (fig. 5C- B) by using a hose clamp and attach
it to the wall outlet/chimney. If the product shall be turned,
this must be taken into consideration in terms of the length
of the tube
Make sure to have assistance and lift the product carefully
up.