3 - Description

Pump

Diaphragm pump with 6 diaphragms, model 364.
Standard speed = 540 rpm (6-spline shaft).
The design of the diaphragm pump is simple, with easily accessible
diaphragms and valves, which ensures that liquid does not contact the
vital parts of the pump.
Pump model 364 is shown on the picture.

Filters

A suction filter is fitted on the sprayers left side, just in front of the manifold valves. It is indicated with a red hose tail.
A Cyclone pressure filter is fitted to the sprayers left side just behind the manifold valves. It has a built-in self-cleaning
function.
In-line pressure filters can be fitted at each boom section as an option.
Nozzle filters are fitted at each nozzle.
μ
ATTENTION! All filters should always be in use and their function should be checked regularly. Pay attention to the
correct combination of filter and mesh size. For more, see the chapter "Technical Specifications" in this book.
μ
ATTENTION! Always run your sprayer with cleaned filters to ensure proper functions and to protect the interior of the
pump.