5 - Operation

Standard Cleaning

μ
ATTENTION! For cleaning between spray jobs, where crops are not very sensitive towards chemicals just sprayed.
1. Engage the pump with tractor in idle, so that pump speed is as low as possible (approx. 250 rpm).
2. Turn the suction valve towards
RinseTank content into the main tank. It is important to have full agitation for approximately 20 seconds, and then close
the agitation valve completely.
3. Turn the suction valve towards
seconds.
4. Turn all sections on. Spray until air comes out of nozzles. When the boom is completely empty, close the main ON/OFF
valve.
Repeat the following 3 steps 5 times:
1. Turn the suction valve towards
RinseTank content into the main tank.
2. Turn the suction valve towards
seconds.
3. Turn all sections on. Spray until air comes out of nozzles. When the boom is completely empty, close the main ON/OFF
valve.
96
and the pressure valve towards
and the pressure valve towards
and the pressure valve towards
and the pressure valve towards
while transferring approximately 1/6 of the
with all sections off for approximately 45
while transferring approximately 1/6 of the
with all sections off for approximately 45