Tekniske data
Technical data
Technische Daten
Caractéristiques Techniques
Forsyningsspænding
Nominel spænding (V
):
bat
Spændingsområde (V
):
bat
Max ripple:
Supply voltage
Rated voltage (V
):
bat
Voltage range (V
):
bat
Max ripple:
Olieviskositet
Oil viscisity
Ölviskositet
Viscosité de l'huile
Filtrering
Filtering
Filtrierung
Filtage
Omgivelsestemperatur
Omgivelsestemperatur
Umgebungstemperatur
Température ambiante
6
12 V version
24 V version
12 V
24 V
11 V - 15 V
22 V - 30 V
5%
5%
12 V version
24 V version
12 V
24 V
11 V - 15 V
22 V - 30 V
5%
5%
Range: 12 - 75 mm
2
/s [66 - 350 SUS]
Min.: 4 mm
/s [40 SUS]
2
Max.:
460 mm
2
/s [2130 SUS]
Max. degree of contamination
(ISO 4406): 19/16
Min.: -30°C
Max.: 60°C
520L0286 • Rev CB • Mar 2014
Versorgungsspannung
Nennspannung (V
):
bat
Spannungsbereich (V
):
bat
Max. Klirrfaktor:
Tension d'alimentation
Tension nominale (V
):
bat
Plage de tension (V
):
bat
Ondulation résiduelle max.
Pilottryk (over tanktryk)
Pilot pressure (over tank)
Pilotdruck (über Tank)
Pression pilote (réservoir)
Olietemperatur
Oil temperatur
Öltemperatur
Température de l'huile
12 V version
24 V version
12 V
24 V
11 V - 15 V
22 V - 30 V
5%
5%
12 V version
24 V version
12 V
24 V
11 V - 15 V
22 V - 30 V
5%
5%
Nom: 13.5 bar [196 psi]
Min.: 10 bar [145 psi]
Max.:
15 bar [217 psi]
Range: 30 - 60°C
Min:
-30°C
Max:
90°C
© Danfoss A/S, 2014-03