Tdr Measurement; Auto-Tdr; Zo Impedance; Tdr Range - H Heuer Instruments UMDT51A User Manual

Line tester lt51 200 hz – 2.2 mhz
Table of Contents

Advertisement

TDR Measurement

You can use the TDR Measurement to determine the length of a cable and to
precisely locate faults such as Shorts, Breaks or Opens, Bridged Tap, Load
Coils, Splices or Splits. During the TDR measurement, the LT51 continually
applies a Pulse to the RTXa-b terminals. As the pulse travels down the pair
(connected to the RTXa-b terminals), any impedance change or fault
encountered will result in some of the pulse being reflected back to the LT51.
These reflections together with the launch pulse are recorded by the LT51 as a
trace and displayed on the LCD, so that the distance between the events can be
measured:
Connect the pair to be tested to the RTXa-b terminals.
Press the

Auto-TDR

When the
key is pressed, the LT51 will automatically search for the first
impedance discontinuity (open, short, bridged tap upto 3km, PVF=67%) and
place the marker at the start of the event, displaying the distance to the event. It
will automatically search all ranges from the lowest to the highest, and zoom the
waveform to show all features in the display.

Zo Impedance

An impedance of 50 or 75

TDR Range

The TDR Range needs to be set to cover the expected length of the cable being
tested:
Press the [f1] soft-key to select TDR Range.
Turn the knob clockwise to increase, or anti-clockwise to reduce, the TDR
Range.
Press the
NOTE: The values for TDR Range are affected by the PVF setting.

PVF (Propagation Velocity Factor)

For the LT51 to display the trace with accurate distance information, the correct
PVF of the cable being measured must be set:
Press the [f2] soft-key to select PVF.
Turn the knob clockwise to increase, or anti-clockwise to reduce, PVF.
Press the
.
NOTE: Changing the PVF will automatically update the TDR range, distance
resolution (centre of bottom bar) and distance display on the LCD.
LT51 User Manual
key, to select the TDR measurement of the LT51.
can be set (via
key (or any key) to clear the dialog box.
key (or any key) to clear the dialog box.
Making Measurements
or
keys) for TDR.
60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lt51

Table of Contents