Overview

The Sensor IQ DALI Control Option Card (IQ-DALI) controls 24 loops of 64 DALI compatible fluorescent
ballasts in broadcast mode. This document details the installation of this card in the Sensor IQ Intelligent
Breaker Panel. Information on installing option cards in other ETC panels is available at etcconnect.com.
Note:
It is best to install any panel option kits after conduit rough-in and load wiring terminations are
complete to reduce the likelihood of damage to the option card. Reference the
Installation Manual

Installation

The DALI Control Option Card can be installed on either interior wall of the low voltage
cavity.
1:
There are four plastic standoffs included with the option card kit. Align the standoffs with the
mounting holes on the option card so the fins are located opposite the connectors.
2:
Press gently until the plastic tabs pass through the mounting hole, locking into place.
3:
Align the standoffs with the mounting holes on the interior of the low voltage cavity.
4:
Press gently until the plastic tabs pass through the mounting hole, locking the option card into place.

Connect Wiring

Note:
• The Sensor IQ DALI Control Option Card provides four bus connections for termination of up to
24 DALI loops total.
• A screw connector is provided for each bus, and is labeled for ease of identification of each output.
• Each terminal accepts 4–0.25 mm
Understanding 0-10V LED Drivers
Corporate Headquarters Middleton, WI, USA +1 608 831 4116 London, UK +44 (0)20 8896 1000
Holzkirchen, DE +49 (80 24) 47 00-0 Rome, IT +39 (06) 32 111 683 Hong Kong +852 2799 1220 Paris, FR +33 1 4243 3535
Web
© 2020 Electronic Theatre Controls, Inc. Trademark and patent info:
Product information and specifications subject to change. ETC intends this document to be provided in its entirety.
7131M2160 Rev B Released 2020-06
Control wiring must be routed in separate conduit from the line voltage wiring for DALI
ballasts.
etcconnect.com
Support
support.etcconnect.com
DALI Control
Option Card
Install option card on
either interior wall.
2
(12–24 AWG) Class 2 or Class 1 wire. See the white paper
for Class 2 and Class 1 wiring considerations.
Contact
etcconnect.com/contactETC
etcconnect.com/ip
Sensor IQ
Mounting
hole
Fins
Standoff

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sensor IQ DALI Control Option Card and is the answer not in the manual?

Questions and answers

Summary of Contents for ETC Sensor IQ DALI Control Option Card

  • Page 1 Control wiring must be routed in separate conduit from the line voltage wiring for DALI ballasts. • The Sensor IQ DALI Control Option Card provides four bus connections for termination of up to 24 DALI loops total. • A screw connector is provided for each bus, and is labeled for ease of identification of each output.
  • Page 2 ETC Installation Guide DALI Control Option Card Note: The associated output loop terminal number should always match the relay circuit number inside the relay panel. For example: If relay 1 is connected to a DALI ballast load, control wiring would terminate to the IQ-DALI option board output terminals labeled “+ 1 -”.

This manual is also suitable for:

Iq-dali

Table of Contents