  • Page 1 Leica DI C800 User Manual / Installation Instructions 10 743 250 – Version 00...
  • Page 2 In developing our systems, we have placed great emphasis on simple, self-explanatory operation. Nevertheless, we suggest studying this manual so that you know and are able to utilize all the benefits of your Leica DI C800 in an optimum way. For valuable information about Leica Microsystems products and services and the address of your nearest Leica representative, please visit our website: www.leica-microsystems.com...
  • Page 3 Chapter overview Chapter overview Introduction Assembly Installation Operation Safety Notes Messages and Warnings Specifications Leica DI C800 / Ref. 10 743 250 / Version 00...
  • Page 4: Table Of Contents

    Directions for the user of the instrument Dangers during use Messages and Warnings Troubleshooting the mirrored data Troubleshooting the display Troubleshooting the optical system Specifications Electrical data Physical data Ambient conditions Standards Accessories Compatibility Leica DI C800 / Ref. 10 743 250 / Version 00...
  • Page 5: Introduction

    Copy this information to the line below so that it is handy in case you have technically correct and efficient way. questions for our representatives or service locations. Action required; here, you are requested to take action. ➩ Type: Serial No.: Leica DI C800 / Ref. 10 743 250 / Version 00...
  • Page 6: Design And Function

    Overview of the typical load for the Accessories provided Leica DI C800 • XGA video cable (for connecting the Leica DI C800 to the workstation or to a PC) • Leica DI C800 User Manual / Installation Manual (10 743 250) Function of the Leica DI C800...
  • Page 7: Assembly

    (at the beam splitter or at the second observer attachment) and remove the protective cover. ➩ Carefully insert the Leica DI C800 and fasten the clamping screw in place. Pay attention to the maximum load of the Leica surgical microscope during assembly of the Leica DI C800, see the microscope's User Manual.
  • Page 8: Connecting The Leica Di C800

    3 XGA video cable (for a PC or workstation) (marked in blue) Look out for pinching of the CAN connecting cable (2) that may occur when laying the cable. Leica DI C800 / Ref. 10 743 250 / Version 00...
  • Page 9: Installation

    Setting up the Leica DI C800 Registering the Leica DI C800 at the control unit Set the minimum and maximum for brightness on the Leica DI C800 ➩ Select the "Setup" entry in the "Service" menu. ➩ Select the "Setup" entry in the "Service" menu.
  • Page 10: Checking The Installation

    Manually switch on/off the display containing overlaid data • Testimage Superimpose a test image in the eyepiece of the Leica DI C800 • Video signal is (in)correct Shows the status of the video signal Leica DI C800 / Ref. 10 743 250 / Version 00...
  • Page 11: Operation

    Assigning Leica DI C800 functions to footswitches or handles If a Leica DI C800 is connected and enabled, the "DI C800" function group is offered If a Leica DI C800 is connected and enabled, an additional "DI C800" tab appears in in the selection.
  • Page 12: During The Surgery

    Operation During the surgery If a Leica DI C800 is connected and enabled, an additional "DI C800" quick access button appears in the static menu bar. Changing the current brightness of the overlay ➩ Click the "DI C800" quick access button.
  • Page 13: Safety Notes

    ➩ Protect the Leica DI C800 from improper operation. ➩ Remove dust on the optics of the Leica DI C800 using a bellows and a soft brush. • Only use the Leica DI C800 as described in this manual. Failure to observe these instructions may result in property damage.
  • Page 14: Messages And Warnings

    Possible cause 1: The data source does not emit an image. ➩ Check whether the "DI C800" quick access button is present on the user interface. The plug connection for the XGA video cable is defective or the XGA video cable is connected incorrectly.
  • Page 15: Specifications

    +24 V DC / max. 30 W Accessories Graphics interface RGB signals 0.7 V p–p / 75 Ohm Both 8.33x and 10x eyepieces can be used for the Leica DI C800. H sync and V sync VESA Standard 60/70/75 Hz at 1024(H) x 768(V) pixels Compatibility...
  • Page 16 +65 6773 0628 10 743 250en/00 • Copyright © by Leica Microsystems (Schweiz) AG, Medical Division, CH-9435 Heerbrugg, 2012 • Printed – IV.2012 – Data prepared by galledia • Subject to modification. • LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.