  • Page 1 SRP-300 Digital Bench Scale Operation Manual Revision 1.2 August 24, 2000...
  • Page 2 © 1995-2000 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway Buffalo Grove, IL 60090 Tel (847) 419-9180 Fax (847) 419-1515 E-mail: transcell@transcell.net Web: www.transcell.net...
  • Page 3: Table Of Contents

    Table of Contents Introduction ..................1 Installation and Wiring................ 1 Keyboard Functions ................2 Configuration..................2 User Menu Descriptions ..............3 Calibration ..................4 Displayed Error Messages ..............4 Specifications ..................5 Warranty and Service Information............6 Introduction The SRP Series Digital Bench Scale is a unit can transmit data on demand, or con- large (18”...
  • Page 4: Keyboard Functions

    Keyboard Functions Toggles between lb and kg units if this key is enabled in the User Menu. CAPACITY : CLASS 300x0.1 lb = 3000 150x0.05 kg Sets indicator to display "0" Zero Tare Motion when in Gross mode, and ZERO within zero band range.
  • Page 5: User Menu Descriptions

    Format 3√ √ "1" = Toledo 8213 Format "2" = NCI 3825Format "3" = Transcell Technology Format "4" = Fairbanks 70-2453-4 Format Allows the lb/kg key to be disabled so that an operator cannot acci- 1√ √ dentally press the key and change the displayed units.
  • Page 6: Calibration

    Calibration All SRP Series scales may be calibrated with any precision test weight from 10% to 100% of the scale’s capacity. The recommended test weight is about 2/3 of the full-scale capacity, but in general, the larger the test weight, the more accurate the scale will be. The only restriction is that the test weight must be in pounds.
  • Page 7: Specifications

    Specifications CONSTRUCTION: OPERATING TEMPERATURE RANGE: Indicator: Black ABS with steel 14°F to 104°F back plate. (–10°C to 40°C) Base: Steel with stainless steel OPTIONAL SWIVEL POST: platform. 18" Tall Stainless Steel Construction DISPLAY: 7 Digit, 0.5", 7-Segment POWER SOURCE: Vacuum Fluorescent AC Adapter, 12VDC, 800mA, included NIST CLASSIFICATION:...
  • Page 8: Warranty And Service Information

    Twelve (12) months from date of shipment from manufacturer. These warranties are made upon the express condition that: 1) Transcell Technology, Inc. is given prompt written notice upon discovery by Buyer of such non-conformity, with a detailed explanation of the alleged deficiencies;...