WARNING:
 The unit must be dry before restarting operation.
CAUTION:
 Do not use a wire brush or other sharp, abrasive
items.
 Do not use any acidic or abrasive detergents.
 Do not damage the refrigerant circuit.
Cleaning the appliance including interior
 Clean the appliance interior, the exterior surfaces,
the accessories and the door seal regularly with
warm water and mild detergent; or with a clean,
damp microfiber cloth without cleaning agent.
 Remove the appliance content and storage it at a
cool location.
 After everything was thoroughly dried, you can
restart the operation.
Defrosting
CAUTION:
Never use metal objects (e.g. knifes) to remove ice
from the evaporator. Otherwise it can be damaged.
To achieve better cooling and to save energy, defrost
the appliance regularly manual as follows:
 To start the defrosting process, turn the tempera-
ture control to the off state and disconnect the
appliance from the power supply.
 Remove the food items and keep covered at a
cool location.
 Once the ice has melted, empty the condensation
drip tray below the chilling compartment; wipe up
the condensation water and dry the unit interior.
 Then you may restart the appliance by connecting
the plug and turning the temperature control.
Changing the bulb
 Loosen the screw and remove the lamp cover
carefully.
 Change the defective bulb.
 Replace the lamp cover properly and fix it.

Troubleshooting

Before you contact an authorized specialist
Problem
Cause / Action
Unit is not
∙ Check the power supply / temper-
working
ature setting / ambient temperature.
properly or
∙ Unblock the ventilation openings,
at all
install the appliance freely.
Loading is
∙ Check the temperature setting /
too warm
ambient temperature. ∙ Open the
door only as long as necessary.
Loud noise
∙ Check the appliance position.
during op-
∙ See the section "Operating noise".
eration
Water on
∙ Check the temperature setting /
the unit
the condensation drip tray.
bottom
Light does
∙ Check the power supply.
not work
∙ See "Changing the bulb".
NOTE:
If a problem persists after following the steps above,
contact your trader or an authorized technician.
21
Lamp data:
max. 10 W / 220-240 V~