Setting and Indication
Setting/Display Listing
Digital display and operation list
DIP
DIP
Rotary switch
Mode
switch
switch
(Knob) position
SW13-8
SW13-7
OPERATION
OFF
OPERATION
MODE
STANDARD
SETTING
OFF
OFF
PRESSURE
FREQUENCY
SUCTION
DISCHARGE
ALM HISTORY
OFF
OPERATION
MODE
STANDARD
SETTING
PRESSURE
ON
OFF
FREQUENCY
SUCTION
DISCHARGE
ALM HISTORY
OFF
OPERATION
MODE
OFF
ON
STANDARD
SETTING
PRESSURE
FREQUENCY
SUCTION
DISCHARGE
ALM HISTORY
Display/Setup
Low pressure and high pressure is
displayed alternately.
ON
"ON value"
"OFF value"
Operation mode
Standard pressure selection
Hi / Med / Lo pressure
Compressor Rotational Speed
Suction gas temperature
Discharge gas temperature
Alarm history error code display
ON
"ON value" setting
"OFF value" setting
"Diff. value" setting
Forced stopping time setting
Protocol type selection
Address setting
Operation mode
―
―
ON
Hi / Med / Lo pressure display
Other temperature display
―
Electronic expansion valve opening
―
Compressor current
Gas cooler fan speed
―
Ambient temperature
Low pressure:
Lo.0.00 to 9.98 (MPa)
High pressure:
Lo-H, 0.00H to *** H (MPa)
0.76 to 5.00 (MPa)
0.68 to 4.92 (MPa)
[FrE] display
[F] display
High pres: *** H (MPa)
Med pres: *** c (MPa)
Low pres: *** (MPa)
** . ** (s
-1
)
**** (°C)
**** (°C)
E *** (Error code)
Latest 50 items
(Older data erased)
0.76 to 5.00 (MPa)
0.68 to 4.92 (MPa)
0.08 to 1.84 (MPa)
30 sec to 180 sec
(1 sec increment)
1.PAn 2.oth 3.Mod
0: No communication (Setting at
shipment)
1 to 49: Pan/oth
1 to 50: Mod
"FrE" display
―
―
High pres : *** H (MPa)
Med pres : *** c (MPa)
Low pres : *** (MPa)
Suction :
****(°C)
Unit outlet :
****(°C)
Split cycle outlet : ****(°C)
Gas cooler outlet : ****(°C)
―
MOV3: 1. *** (step)
MOV4: 2. *** (step)
―
**** (A)
**** (rpm)
―
**** (°C)
EN - 33
Remarks
▲ pressing: Red LED blinking
cancelled
During pressing ▼: evaporating
temperature
Pressing ▼ and release: low pressure
(Only when no error is indicated)
Setting cannot be changed.
▲ pressing: "Lim value"
▼ pressing: "Diff value"
Setting cannot be changed.
▲ pressing: Up the set value
▼ pressing: Down the set value
▲ pressing: displayed data change
▼ pressing: displayed data change
[Ex] In the case of 10 (s
-1
)
→ xx.0
In the case of less than 10 (s
)
-1
→ x.00
▲ pressing: Suction heating rate(K)
▼ pressing: Unit outlet temperature
(°C)
▲ pressing: Older data
▼ pressing: Newer data
▲ pressing: Up the set value
▼ pressing: Down the set value
▲ pressing: Up the set value
▼ pressing: Down the set value
Setting cannot be changed.
―
―
▲ pressing: displayed data change
▼ pressing: displayed data change
―
▲ pressing: displayed data change
▼ pressing: displayed data change
―
―
―
▲ pressing: Software Version
▼ pressing: Erase Alarm history
―