Setting
HDBaseT
SDI Settings
Options
Control Communications
Extron XTP
Link Type
Manual Settings
249
Description
Selects the communication
settings for connections to an
HDBaseT transmitter or switcher
Control Communications:
enables or disables
communication from the Ethernet
and serial ports on the
transmitter; turning on this setting
disables the projector's LAN, RS-
232C, and Remote ports (Extron
XTP must be turned off to use
this setting)
Extron XTP: set to On when you
connect an Extron XTP
transmitter or switcher to the
HDBaseT port
The fan may rotate when this
setting is set to On.
Select the signal settings for the
SDI port
Link Type: select Single (Auto)
to let the projector read the
payload ID for the input signal
and automatically display the
image, or select Single (Manual)
when you know the type of input
signal and want to select the
same signal in the Manual
Settings options
Manual Settings: set various
SDI settings manually or reset
them to their default values