ESAB Cutmaster 120 Operating Manual page 63

Plasma cutting system
Hide thumbs Also See for Cutmaster 120:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
The plasma gas flows into the torch through the
negative lead, through the starter cartridge, around
the electrode, and out through the tip orifice.
The secondary gas flows down around the outside
of the torch starter cartridge, and out between the
tip and shield cup around the plasma arc.
C. Pilot Arc
When the torch is started a pilot arc is established
between the electrode and cutting tip. This pilot arc
creates a path for the main arc to transfer to the work.
D. Main Cutting Arc
DC power is also used for the main cutting arc. The
negative output is connected to the torch electrode
through the torch lead. The positive output is con-
nected to the workpiece via the work cable and to
the torch through a pilot wire.
E. Parts - In - Place (PIP)
The torch includes a 'Parts - In - Place' (PIP) circuit.
When the shield cup is properly installed, it closes
a switch. The torch will not operate if this switch is
open.
Torch Switch
To Control
Cable Wiring
PIP Switch
A-02997
Parts - In - Place Circuit Diagram for Hand Torch
300X5398
Torch Trigger
Parts - In - Place Circuit Diagram for Machine Torch
Shield Cup
INTRODUCTION
ESAB CUTMASTER 120
Remote Pendant
PIP Switch
To ATC
CNC Start
PIP Switch
To ATC
Automation Torch
PIP Switch
To ATC
Shield Cup
Shield Cup
Shield Cup
2T-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl100 1torch

Table of Contents