Technical Data - GEM 3040 Operating Instructions Manual

Ultrasonic flowmeter
Table of Contents

Advertisement

6 Technical data

6 Technical data
6.1 Medium
Working medium:
6.2 Temperature
Media temperature:
Ambient temperature:
Storage temperature:
6.3 Pressure
Operating pressure:
Pressure rating:
Pressure loss:
GEMÜ 3040
Corrosive, alkaline, toxic, inert and liquid media, including DI water, which have no negative impact
on the physical and chemical properties of the respective valve body and seal material.
DN 10–25:
-10 – +80 °C
DN 32–50:
0 – +50 °C
DN 10–25:
0 – +60 °C
DN 32–50:
-15 – +50 °C
0 to 40 °C
0 to 16 bar
DN 10–15:
PN16
DN 20–50:
PN10
Pressure loss with water at 22 °C, 100 kPa = 1 bar
DN25 (code 25)
DN32 (code 32)
Flow [l/min]
Flow [l/min]
8 / 34