2 Safety

2.1 Intended Use

The system is used for digital stereo magnification in 2D and 3D in real time and for documentation.

2.2 Unintended Use

Only spare parts and accessories supplied or authorized by PCE Instruments may be used with this product. If other
spare parts or accessories are used, this could have a detrimental effect on the safety of the device, increase the risk
of serious injury, and lead to damage to the environment or the device itself.

2.3 Ambient Conditions for Safe Operation

The appliance should only be operated:
indoors
up to 2,000 meters (6,562 ft) above sea level
at an ambient temperature of 5 – 35 ºC [41 – 95 ºF] *)
at a maximum relative humidity of 80 % at 31 ºC [87.8 ºF], linear reduction up to 50 % relative humidity at 35 ºC [95 ºF] *)
with mains electricity supply provided that the voltage fluctuation is within 10 % of the rated value
with Pollution Degree 2
with Overvoltage Category II
*) The unit can be used at a temperature of 5 – 30 ºC [41 – 86 ºF] and at a humidity of up to 80 %. At
temperatures of
31 – 35 ºC [87.8 – 95 ºF], the humidity must reduce proportionally to ensure that the unit can be operated (e.g. at
33 ºC [91.4 ºF] = 65 % humidity, at 35 ºC [95 ºF] = 50 % humidity). The unit should not be operated at
temperatures above 35 ºC [95 ºF].

2.4 Ambient Conditions for Storage and Transport

For storage and transport, the following ambient conditions must be maintained:
Ambient temperature of -20 – +60 ºC [-4 – +140 ºF]
Maximum relative humidity of 80 %

2.5 Hazard and Warning Notes

2.5.1 General Information
► If the unit is not operated according to this instruction manual, the intended protection cannot be
ensured anymore.
► The unit should only be operated using a mains cable with a country-specific plug system. Any
modification required should only be carried out by an electrician.
► The unit should only be operated if the data on the type plate corresponds with the data of the regional
mains voltage.
► The unit should only be plugged into earthed sockets.
► The mains socket should be easily accessible.
► Disconnect the unit from the mains before working on electrical parts.
► Regularly check connecting cables (such as power cables), hoses, and housing (for example, the
control panel) for damage (for example, kinks, tears, porosity) or deterioration due to aging. Do not
operate units with damaged connection cables, hoses, or housing parts, or other defects.
► Damaged equipment must be taken out of service immediately. Disconnect from mains and secure
against being switched on again. Send the device in for repair.
► Operate the equipment only under supervision.
► Observe national accident prevention regulations.
► It is the responsibility of the operator that national regulations during operation and regarding a