7

Servicing and troubleshooting

7.1
Magnetic test point
A magnetic test point is marked on the side of the housing to allow a
functional test of the Rosemount 2120 in the overall system. By touching a
magnet to the target, the output from the level switch will change state
while the magnet is present.
Figure 7-1: Magnetic Test-point Function
Output off
Output on
7.2
Maintenance and inspection
Only use a damp cloth for cleaning.
Visually examine the level switch for damage. If it is damaged, do not
use.
Ensure the housing cover, cable glands, and blanking plugs are fitted
securely.
Ensure the LED flashing rate is 1 Hz or constantly on. (See
other flashing rates).
34
Metal housing
TP
Glass-filled-nylon
housing
DIRECT LOAD SWITCHING
MAGNETIC
~
TEST
Supply
20 - 264Vac
POINT
50 - 60Hz 2VA
20 - 60Vdc 0.5W
2120D0AS1NAAA
Output Rating:
Load 20 - 500mA
41001029
MAX WORKING PRESSURE AT 20°C: 0.25 bar
MAX PROCESS TEMPERATURE: 150°C
MADE IN UNITED KINGDOM
*41001029*
www.rosemount.com
No magnet
TP
TP
DIRECT LOAD SWITCHING
MAGNETIC
~
TEST
Supply
20 - 264Vac
POINT
50 - 60Hz 2VA
20 - 60Vdc 0.5W
2120D0AS1NAAA
Output Rating:
Load 20 - 500mA
41001029
MAX WORKING PRESSURE AT 20°C: 0.25 bar
MAX PROCESS TEMPERATURE: 150°C
MADE IN UNITED KINGDOM
*41001029*
www.rosemount.com
MAGNETIC
Magnet
Output on
Output off
Rosemount 2120 Level Switch
June 2020
TEST
POINT
Table 6-1
for

Advertisement

loading