Alarm Inputs - Bosch AUTODOME IP starlight 5100i User Manual

Hide thumbs Also See for AUTODOME IP starlight 5100i:
Table of Contents

Advertisement

58
en | Alarm
Destination address
Enter the e-mail address for alarm e-mails here. The maximum address length is 49 characters.
Sender address
Enter a unique name for the e-mail sender, for example the location of the device. This will
make it easier to identify the origin of the e-mail.
Note: The name must include at least two character groups separated by a blank (for example,
Parking Garage) in order for the system to generate an email from that name, as in "From
Parking Garage". Text with only one group of characters (for example, Lobby) will not
generate an email.
Test e-mail
You can test the e-mail function by clicking the Send Now button. An alarm e-mail is
immediately created and sent.
9.5

Alarm Inputs

Active
Configure the alarm triggers for the unit.
Select N.C. (Normally Closed) if the alarm is to be triggered by opening the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by closing the contact.
Select N.C.S. (Normally Closed Supervised) if the alarm is to be triggered by opening the
contact.
Select N.O.S. (Normally Open Supervised) if the alarm is to be triggered by closing the
contact.
A supervised alarm transmits both the alarm condition and the tamper condition. Depending
on how the alarm is configured, a short or a break in the alarm's circuit can trigger the tamper
signal.
(NCS and NOS contacts are only present on some cameras)
Name
You can enter a name for each alarm input. If the Live functions are configured accordingly,
this name is displayed below the icon for the alarm input. You can also use the name in the
Forensic Search program function as a filter option for quick search in recordings. Enter a
unique and clear name here.
Caution!
Do not use any special characters, for example &, in the name.
!
Special characters are not supported by the system's internal management.
Note: This name appears in the Digital I/O section of the Live page.
Action
Select a type of action to be performed when an alarm input occurs:
(only available on some cameras)
2020-11 | draft 0.9 |
None
Monochrome
This switches the camera to the monochrome mode.
Switch mode
When this is selected, you can select the Scene Mode to be used for the active and
inactive period of the alarm.
User Manual
AUTODOME IP starlight 5100i
Bosch Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents