Page 1
PD2-3012-4 Coarse Fine Power Error Ext Mode High External control connector D-Sub25pin 4-M3 depth 5 External Control 100-240V- 50/60Hz 78VA 85X140 (Mounting) 12.5 12.5 CCS Inc. Copyright(c) 2006 CCS Inc. All rights reserved. Reproduction or photocopy without permission is prohibited.
Page 2
PD2 Series provides a more linear and repeatable intensity control because of the force-detent adjustment course/fine adjustment knobs and benefits of pulse duty control. The PD2 Series is suitable for all CCS lights without dedicated power supplies. The Series is designed to meet the requirements of the widest variety of applications with the 12 and 24V options, power ratings range, and the number of independent output channels.
Page 3
1. Safety Precautions *Read this instruction guide before using the product. Thank you for purchasing a CCS product. To properly use the product, please read this instruction guide before use and keep it for your future reference. Be sure to pay special attention to the information marked with “...
Page 4
3. The PD2-3012-4(A)/8(A) can supply up to 12V at 2.25A (27W) or 2.08A (25W) and the PD2-3024-4(A)/8(A) can supply up to 24V at 1.13A (27W) or 1.05A (25W) for CCS LED lighting. Do not exceed the maximum wattage for the total number of circuits.
Page 5
Turning ON lighting 1. Check the power supply switch to make sure it is turned OFF. Front Power OFF The illustration shows an 8-channel model, but the 4-channel model operates the same way. Connect the LED lighting to the power supply. Plug the AC power cord of the power supply into a wall socket.
Page 6
CH.5 CH.6 CH.7 CH.8 Structure (Output) A driver IC or an open collector outputs a signal to each terminal and the external control signals are input to the product at CMOS level. Optional external control cable is manufactured by CCS.
Page 7
The product support the following types of external control. - External and manual light intensity control selection - Channel selection - Light intensity settings - Lighting ON/OFF control - Overcurrent protection signal monitoring External control 1. Connect the external control cable to the power supply. (Also connect the lighting and any other devices.) Power supply (rear view) External control cable...
Page 8
Note: Light intensity settings are enabled only as long as the power supply remains ON and will be lost when the power supply is turned OFF. Light steps B7 [MSB] B0 [LSB] Coarse Fine intensity(%) 99.2 99.6 100.0 4) Lighting ON/OFF control After you have selected the light intensity level, Use bit B13 to 20 for channels 1 to 8) for ON/OFF control.
Page 9
Write sequence >100µs B11 (EXT) NPN open collector ON >100µs >100µs B8 to B19 (CH) Channel selection n Channel selection n + 1 >100µs >100µs B0 to B7 Light intensity data CH. n + 1 Light intensity data CH. (Light intensity bit) >300µs Write B12 >300µs...
Page 10
2. External control connectors: 25-pin D-sub male with M2.6-mm screws Each signal is pulled up to the 5V in the internal circuits with resistance. Use a shielded cable of 3m or less for the control line. Signal Signal number number Light intensity B0 External control B11 (INT/EXT) (LSB)
Page 11
5. PD2 input circuit (negative logic) Light intensity data: B0 to B7 Control signals: CH, EXT, WR, and OFF Output using a driver IC or NPN open collector Ω 2.2k The 24V output of the sequencer cannot be 74HC14 input as it is. (Maximum allowable input voltage: 5.5V) PD2 side: Ω...
Page 12
8. Dimensional Diagrams (mm) PD2-3012-4(A) / PD2-3024-4(A) Supplied 3-prong AC power cord (2m)
Page 13
PD2-3012-8(A) / PD2-3024-8(A) Supplied 3-prong AC power cord (2m)
Page 14
9. Specifications Models PD2-3012-4(A) PD2-3024-4(A) PD2-3012-8(A) PD2-3024-8(A) Input voltage (Rating) 100-240V AC [*1] Power consumption 78VA typ. (typ.) frequency 50/60Hz Leakage current 3.5mA max. (264V AC, 60Hz, under full-load condition) Operates at 107% min. Overcurrent protection [*2] Automatically reset, or manually reset by turning power OFF then ON again. Between input and 1500V AC for one minute 10mA max.
Page 15
Care and Handling Warning - Turn OFF the Power Supply and unplug it from the outlet before handling. Caution - Do not scratch the unit by handling it with a hard object. - Do not let water or cleanser enter the unit. - Do not use cleansers or chemical agents other than those listed below.
Page 16
China RoHS Directive China RoHS Directive is formally known as "Management Methods for Controlling Pollution by Electronic Information Products", which was implemented on March 1, 2007 in China. Same as EU RoHS Directive, this regulation restricts the usage of six substances such as lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated diphenyl ether (PBDE).
Page 17
Warranty period: Two years (one year for radiant quantity), starting from CCS Inc. shipping date. CCS Inc. will repair or replace the product free of charge if it should fail to function or if the radiant quantity of the product should drop to 50% or less of its initial radiant quantity within the specified warranty period.
Page 18
Head Office http://www.ccs-grp.com Shimodachiuri-agaru, Karasuma-dori intlsales@ccs-inc.co.jp Kamigyo-ku, Kyoto 602-8011 Japan Phone: +81-75-415-8284, Fax: +81-75-415-8278 Copyright(c) 2008 CCS Inc. All Rights Reserved. Description in this instruction guide is based on the information as of April 2008. KZ01894-T001-000...