  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2: Safety Precautions

    Operation Manual for the PD2 Single Channel Series Power Supply Units for LED Lighting PD2-1012/1024/3012/3024/5024 1. Safety Precautions *Be sure to read prior to using the product. Thank you for purchasing this Power Supply for LED Illumination. Please read this Operating Manual before using the product, and follow its instructions to ensure safe operation.
  • Page 3 2. Overview This power supply is for exclusive use with LED lighting made by CCS. 1. Dimming can be controlled in internal mode from the intensity control knobs on the front panel of the PD2 or in external mode using a PLC, microcomputer, or other device.
  • Page 4                   3. Operating Procedure Turning ON lighting 1. Check the power supply switch to make sure it is turned OFF ( position). Front Note: The illustration shows the PD2-3012/24. All other models operate the same way.
  • Page 5: External Control

    A driver IC or an open collector outputs a signal to each terminal and the external control signals are input to the PD2 at CMOS level. The EXCB2-B3 is an optional external control cable manufactured by CCS. The PD2 support the following types of external control.
  • Page 6 External control 1. Connect the external control cable to the power supply. (Also connect the lighting and any other devices.) Power supply                     (rear view) 2. Input the desired control signal from the external External control connector control cable.
  • Page 7 Manual ON/OFF control Phone jack 1. In manual mode, the external ON/OFF control is available for the for ON/OFF illuminator. control in manual mode (internal 2. Insert the phone plug into the phone jack to send the ON/OFF) ON/OFF control signal for manual control (internal ON/OFF control) control).
  • Page 8 GND(-) Outside Contact your nearest CCS representative if you need to extend the control signal cable or operate in an extremely noisy environment. Cables should not be extended more than 3 m. Potentially harmful noise may be eliminated by installing a 0.01 to 0.1-μF capacitor between the signal and ground to ensure proper operation of this product.
  • Page 9 5. PD input circuit (negative logic)                                         Dimming data: B0 to B7 +5V   Control signals: EXT, WR, and ON Output using a driver IC or NPN open collector (Maximum allowable input voltage: 12 V)  ...
  • Page 10 7. Appearance (mm) PD2-1012/1024 AC power cable (2.3 m) Power switch Output Connectors Coarse intensity Fine intensity External control connector control knob control knob 15 Pin Dsub Four, M3 holes (depth: 3) 54 x 93 (fastening screw holes) (Insertion depth less than 2 mm) Manual ON/FF control Phone jack...
  • Page 11 PD2-3012/3024 Output connector External control connector 15 Pin Dsub Coarse intensity control knob Fine intensity control knob Power switch Four, M3 holes (bottom panel fastening Four, M3 holes (side panel screws) 40 x 140 fastening screws 90 x 140 (Insertion depth less than 5 mm) (Insertion depth less than 5 mm) Supplied AC power cable (2 m) Artisan Technology Group - Quality Instrumentation ...
  • Page 12: Specifications

    To operate CCS lighting without cooling fans, use ON/OFF control to turn OFF the lighting when it does not have to be lit in order to lower the temperature of the lighting.
  • Page 13 Output overcurrent Operates at 107% of the rated current protection The Error indicator (red) on the front panel is lit when overcurrent is detected. (See notes 3) This latch-type protection is restored by restarting the power supply. Insulation/dielectric Between input and output connectors and 2,000 VAC for one minute strength between input connector and frame ground: ...
  • Page 14: Care And Handling

    If a fault or defect attributable to CCS becomes apparent during the duration of the warranty, CCS will in good faith ship a replacement, or replace or repair the defective part of the product free of charge. The following cases, however, are not covered by the warranty.
  • Page 15       intlsales@ccs-inc.co.jp Head Office Shimodachiuri-agaru, Karasuma-dori Kamigyo-ku, Kyoto 602-8011 Japan Phone: +81-75-415-8284, Fax: +81-75-415-8278 Apr. 2006 No. MP-097E B0839-0020-A   Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...