1-1.

Self-diagnosis Function

1-1-1.
Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a four-
digit number appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors
can be checked by referring to this indication of five alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in "Usage and Diag record" on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.
1-1-2.

Self-diagnosis Code Table

Self-diagnosis
Symptom/State
Code
A0-000
System error by software
E10-005
Lens overheating
E10-006
Lens overheating
*1
Handshake correction function does
E10-007
not work well
Handshake correction function does
*1
E10-008
not work well
*1
Image vibration correction during
E10-009
handshake function does not work
E10-00B
Temperature abnormality of the lens
E10-101
Abnormalities in zoom initialization
of the lens
E10-102
Abnormalities in focus initialization
of the lens and abnormalities in zoom
initialization of the lens occurred si-
multaneously
E10-103
Abnormalities in initialization of the
lens
E10-104
Abnormalities in initialization of the
lens
E10-10A
Focus operation failure of the lens
Abnormality of the variable ND fil-
*1
E12-001
ter
*1
Abnormality of the variable ND fil-
E12-002
ter
E40-001
Battery current value goes over the
max discharge current
E40-002
Battery pack temperature goes over
the specified value.
E40-003
Error of battery authentication
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
Section 1

Trouble Shooting

Correction
Ask the headquarters about correction of this error.
Exchange the lens.
Exchange the lens.
Turn the power off and on again.
Turn the power off and on again.
Turn the power off and on again.
Exchange the lens.
Exchange the lens.
Exchange the lens.
Exchange the lens.
Exchange the lens.
Exchange the lens.
Turn the power off and on again.
Turn the power off and on again.
Check the remaining battery power because this symptom maybe de-
pended on the remaining battery level, and confirm whether or not
the symptom is occurred after replacing the battery.
If the symptom is still occurred, IC2300 and IC3102 on the AVP-25
board, or the peripheral circuit may be faulty.
Replace the AVP-25 board.
Change the battery pack or place it in a cool place.
When this error is not cleared, replace the RE-328 board and/or the
AVP-25 board.
Use the Sony genuine battery.
When this error is not cleared, replace the RE-328 board and/or the
AVP-25 board.