MV Units Only - Starting the Pilot

Remove the glass frame before starting the pilot.
The pilot flame is required to ignite the main burners (it
also plays a safety role). It should be left on once lit. It
will stay lit unless the gas control valve is turned to "OFF"
or if the burner has not been lit in a 7 day period (see
"Pilot Fuel Conservation Timer" section on pg.48).
However, the pilot will go out if the gas is shut off, the
propane tank runs out (or low) or if the stove
malfunctions. If the pilot turns off frequently, call your
dealer for information.
NOTE: Suggestions on how to limit the need to restart the
pilot during the heating season can be found on
page 48
To start the pilot follow the directions below:
WARNING:
When lighting or re-lighting the pilot, the glass must be
removed (see page 50).
a
Remove the glass (see page 50 for details).
b
Push the gas control knob in slightly and turn it to the
"OFF" position. The knob will not turn from "ON" to
"OFF" unless the knob is depressed slightly. Wait five
minutes to let any gas that may have accumulated
inside the firebox escape. If you smell leaking gas,
follow the directions on the cover "IF YOU SMELL
GAS".
c
Turn the gas control knob to the "PILOT" position and
press the knob in, this will allow gas to flow to the pilot
light. Press the button on the pilot igniter repeatedly
until you see the pilot light.
WARNING:
If the pilot does not light after 15 seconds, release the
knob and call your dealer for service. Do not attempt to
light pilot until service has been performed.
d
Keep the gas control knob depressed for 30 seconds
once it is lit.
e
Release the gas control knob. If the pilot goes out,
repeat step C. If the pilot refuses to stay lit, call your
dealer for service. With the pilot lit, proceed to step "f".
f
Replace the glass.
g
Turn the gas control knob counter-clockwise to "ON".
The pilot is now lit and the heater can be turned on and
off.