Cable Requirements - American Dynamics SpeedDome Ultra VII EIS Installation And Service Manual

Day/night camera dome
Hide thumbs Also See for SpeedDome Ultra VII EIS:
Table of Contents

Advertisement

Cable Requirements

Data Cable
The table below shows requirements for
SensorNet, RS-422, and Manchester networks. For
more information about communication protocols
and cable networks, see Communication Protocols
and Cable Networks, 8000-2573-19.
Data cable requirements
SensorNet
Cable type
1
unshielded,
twisted
pair*
Wire gauge
22 AWG
Connection
Non-
polarized
Max.
32
devices on
line
*
Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables must
be used in indoor ceilings used for environmental air
return (called "other air space" in the National Electrical
Code). Order parts through your distribution network.
Note: If you order cable from an outside source, wire
colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable (non-
plenum) cable is recommended. Plenum-rated cables
must be used in indoor ceilings used for environmental
air return (called "other air space" in the National
Electrical Code). Order cable directly from Belden by
calling 1-800-235-3361.
Power Cable
For the camera dome to operate properly, line
voltage must not go below the worst-case low line
voltage shown in the following table. Make cable
lengths as short as possible to minimize affects of
low line voltages. As shown in the table, maximum
cable length depends on the Class 2 LPS (low
voltage) ac source (such as a J-box) and the worst-
case low line voltage. These lengths are for
Sensormatic composite cables, which use 18
ac power wires.
SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME
INSTALLATION AND SERVICE GUIDE
RS-422
Manchester
2
1
shielded,
shielded
twisted
twisted
pair*
pair**
22 AWG
18 AWG
Polarized
Polarized
10
3
AWG
Note: Typically, distances are used that provide
a 15% margin between nominal and low line
conditions. For example, if the nominal voltage is
120Vac, restrict cable length to that associated
with 100Vac (0.85 x 120).
Worst-case ac line voltages
Indoor Dome
AC Power Source
28 VA
Transformer
5604-0006-01
50 VA
Transformer
5604-0044-01
1-position SensorNet
RJ1SNUD
1-position SensorNet
RJ1SNUD-1
6-position SensorNet
Indoor J-Box
RJ6SN
10-Position RS-422
Indoor 120V/60Hz J-Box
RJ860AP
10-Position RS-422
Indoor 240V/60Hz J-Box
RJ860AP1
Universal Transformer
0300-0914-01
Universal Transformer
0300-0914-03
7 of 37
Worst-Case
Meters
Low Line V
(Feet)
117
180 (600)
100
130 (430)
90
80 (270)
117
180 (600)
100
150 (500)
90
90 (300)
117
210 (700)
100
130 (430)
90
100 (325)
117
210 (700)
100
130 (430)
90
100 (325)
117
300 (1000)
100
230 (750)
90
160 (530)
240
300 (1000)
200
230 (750)
180
160 (530)
117
275 (900)
100
200 (650)
90
130 (430)
240
275 (900)
200
200 (650)
180
130 (430)
117
200 (650)
100
130 (430)
90
90 (300)
240
200 (650)
200
130 (430)
180
90 (300)
8200-0184-14, REV. A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras918lsRas918lspRas918lsi

Table of Contents