Dome Setup and Attachment

The following procedure explains how to set up and
attach the dome to its base.
Procedure
Ensure that ac power and electrical
signals are off during wire connections!
Connectors used in this procedure are
very delicate! DO NOT overtighten these
connectors. Use the a 0.4 x 2.5mm slotted
screwdriver. Larger screwdrivers can
damage the connector.
CAUTION—ELECTROSTATIC SENSITIVE
DEVICE! Use a grounding strap when
handling the I/O board.
Referring to Figure 3-4:
1. Set communications jumpers.
On the I/O board, set jumper JW1 for "terminated" or
"unterminated" (choose terminated when the dome is
at the end of the line). Set jumpers JW2 and JW3 for
SensorNet communication protocol.
2. Connect the video cable.
Route this outdoor interface board cable through the
board's cable clamp and connect it to the BNC
connector on the I/O board.
3. Connect the data/power cable.
Route this outdoor interface board cable through the
board's cable clamp and connect the its data wires to
the P1 connector on the I/O board as follows:
P1 Connector (RS422 Data Communications)
Pin
Color
Designation
1
Orange
RS422 Data In High (+)
2
Green
RS422 Data In Low (–)
3
Yellow
RS422 Data Out High (+)
4
Brown
RS422 Data Out Low (–)
5
6
P1 Connector (SensorNet Data Communications)
Pin
Color
Designation
1
2
3
4
5
Brown
SensorNet
6
Yellow
SensorNet
OUTDOOR DOME INSTALLATION
4. Connect the alarm input cable, if used.
Route this cable through the board's cable clamp
and connect its wires to the P4 connector on the I/O
board as follows:
P4 Connector (Alarm Inputs)
Pin
1
2
3
4
5
6
Figure 3-4. Electrical connections
SPEEDDOME ULTRA
3-5
Color
Designation
N/A*
Alarm 3 Input (3.5mA sink)
N/A*
Alarm 2 Input (3.5mA sink)
N/A*
Alarm 1 Input (3.5mA sink)
N/A*
Alarm 0 Input (3.5mA sink)
N/A*
Ground
N/A*
Ground
Pin 1
Pin 1
P3
P7
P8
I/O BOARD
JW1 Terminations
PINS
FUNCTION
1-2
Unterminated
2-3
Terminated
JW2/JW3 Terminations*
PINS
FUNCTION
1-2
SensorNet
2-3
For Future Use
*
Jumper locations are
not relevant when the
dome is hooked up to
an RS422 network.
Pin 1
P4
Pin 1
P1