Supported Controllers And Matrix Switching Systems - American Dynamics SpeedDome Optima LT Quick Reference Manual

Programmable dome camera
Hide thumbs Also See for SpeedDome Optima LT:
Table of Contents

Advertisement

Supported Controllers and Matrix Switching Systems

SpeedDome Optima LT may be used with the following controllers and matrix switching systems. See notes below for specific limitations or
restrictions.
ADTT16E
VM32 / AD32
Series
Series
Feature
SensorNet
SensorNet
Supported
Protocols
Maximum
96
Available
Presets
Maximum
Available
3
Patterns
(4)
DirectSet
Yes (6)
menu (5)
NOTES:
(1) For the list of compatible keyboards, see Supported AD Keyboards on page 5.
(2) VM96 performance is limited under 2-wire RS422 simplex. Patterns and presets are not supported in RS422 simplex mode.
(3) Preset information is stored at the host, not the dome. For SensorNet and RS422 duplex, unlimited presets are supported.
(4) Patterns are limited by time and the number of available dome commands. Total time for each pattern cannot exceed 6 minutes 50 seconds.
The total number of dome commands used in the patterns cannot exceed 99.
(5) Although text overlay is not supported, the following DirectSet menu commands are supported: Return to Auto Iris/Focus, Flip, Peel and Dome
Reset. See DirectSet Menu Commands on page 3 for more information.
(6) Requires firmware version 0701-2833-0103 (EEPROM) / 0701-2834-0201 (Flash) or newer.
(7) Requires a compatible keyboard with a DirectSet key (ADCC0200 or ADCC0300).
(8) 2-wire RS422 simplex mode to be supported with the MegaPower 48+ firmware upgrade.
(9) 2-wire RS422 simplex mode to be supported with AD2083-02C code translator firmware upgrade.
SPEEDDOME OPTIMA LT PROGRAMMABLE DOME CAMERA
QUICK REFERENCE GUIDE
VM96 Series
AD2150 /
AD2350
(1)
SensorNet
Manchester
RS-422 (2)
96
Unlimited (3)
64 Manchester
60 RS422 (9)
0 RS422 (2)
3
3 (2)
3
No
No
No
MegaPower
MegaPower
AD1650
LT
48
(2)
(1)
SensorNet
Manchester
Manchester
SensorNet
RS422 (9)
RS422 (8)
96
64 Manchester
64 Manchester
96 SensorNet
60 RS422 (9)
96 RS422 (8)
3
3
Yes (7)
Yes (7)
No
4 of 8
AD168/
AD2050
MegaPower
(1)
168 (1)
Manchester
Manchester
SensorNet
RS422 (9)
RS422 (9)
64 Manchester
64 Manchester
64 SensorNet
60 RS422 (9)
60 RS422 (9)
3
3
3
No
No
MegaPower
1024
(1)
Manchester
RS422 (9)
64 Manchester
60 RS422 (9)
3
No
8200-0181-03, REV. C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Speeddome optima lt rasel series

Table of Contents