Recording Patterns When Configured For 16; Sensornet, Rs-422, Manchester, And Utc Controllers And Switchers - American Dynamics SpeedDome Ultra VIIE Operator's Manual Supplement

Day/night camera dome configuration utility
Hide thumbs Also See for SpeedDome Ultra VIIE:
Table of Contents

Advertisement

3. Use the joystick to highlight the PATTERN
SELECT field and press Zoom In/Out to select
Off
3,
16
,
or
.
4. Use the joystick to highlight EXIT and press
Focus Far to select. The Dome Configuration
Menu appears.
5. Use the joystick to highlight EXIT AND SAVE
CHANGES and press Focus Far to save.
Recording Patterns When
Configured for 16
Recording Patterns when the Pattern Select field
is set for Off, 3, or 16 is accomplished through
keyboard commands (consult your keyboard user
guide). However, additional steps are required
when the Pattern Select field is set for 16.
Follow the steps below to record 16 variable speed
Patterns:
1. Enter the appropriate keyboard commands to
record a Pattern, using 1, 2, or 3 as your
Pattern number (Consult your keyboard user
guide for specific steps.). The Pattern Select
screen appears (Figure 23)
Figure 23.
PATTERN SELECT
1
5
9
1
6
10
3
7
11
4
8
12
EXIT
2. Use the joystick to highlight a desired Pattern
number (1-16). Press Focus Far to continue.
3. Pan/tilt/zoom the dome as desired for the
Pattern.
4. Execute the keyboard's Pattern save
command to save the Pattern.
Running 16 Patterns
When a dome is configured for 16 Patterns,
running a Pattern requires displaying the Pattern
SPEEDDOME ULTRA VIIE DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY
OPERATOR'S MANUAL SUPPLEMENT
13
14
15
16
10 of 15
Select screen (Figure 23). Follow the steps below
to run a Pattern.
1. Enter the appropriate keyboard command to
run Patterns 1, 2, or 3. The Pattern Select
screen appears.
2. Move the joystick to highlight the desired
Pattern number (1-16) to run.
3. Press Focus Far to select. The Pattern Select
screen disappears and the Pattern runs.
SensorNet, RS-422,
Manchester, and UTC
Controllers and Switchers
The following provides information about
SensorNet, RS-422, Manchester, and UTC
protocols on SpeedDome Ultra VIIE compatible
controllers.
VM8
Supported Protocol
Maximum Presets
1
Maximum Patterns
DirectSet Menu
Address Range
Notes:
(1) Apple Peel only. Programmable Patterns are not
available.
VM16/ADTT16 (White Touch
Tracker)
Supported Protocol
Maximum Presets
2
Maximum Patterns
DirectSet Menu
Address Range
Notes:
(1) Requires RCSN422 code converter.
(2) Patterns are limited by time and the number of
available dome commands.
SensorNet
0
1
Not supported
1-8
SensorNet
1
RS-422
96 – SensorNet
4 – RS-422
16
Not supported
1-16
8200-0184-12, REV. A