26.4 Air exchange sensor table voltage - m
There is an offset of 0.2 V due to mechanical design. The air exchange must be properly calibrated
before measuring.
Voltage
Air exchange
[V]
[m
3
/h]
0.20
0
0.30
5
0.50
10
0.65
15
0.80
20
0.85
25
0.95
30
1.05
35
1.15
40
1.20
45
1.30
50
1.35
55
26.5 Air exchange sensor table voltage - m
There is an offset of 0.2 V due to mechanical design. The air exchange must be properly calibrated
before measuring.
Voltage
Air exchange
[V]
[m
3
/h]
0.20
10
0.28
15
0.36
20
0.44
25
0.52
30
0.60
35
0.68
40
0.75
45
0.83
50
0.91
55
0.99
60
1.07
65
1.15
70
Voltage
Air exchange
[V]
[m
3
/h]
1.45
60
1.50
65
1.55
70
1.65
75
1.70
80
1.75
85
1.90
90
1.95
95
2.00
100
2.05
105
2.10
110
2.20
115
Voltage
Air exchange
[V]
[m
3
/h]
1.23
75
1.31
80
1.39
85
1.47
90
1.55
95
1.63
100
1.70
105
1.78
110
1.86
115
1.94
120
2.02
125
2.10
130
2.18
135
Voltage
Air exchange
[V]
[m
3
/h]
2.25
120
2.35
125
2.40
130
2.50
135
2.55
140
2.65
145
2.70
150
2.80
155
2.90
160
3.00
165
3.10
170
3.20
175
Voltage
Air exchange
[V]
[m
3
/h]
2.26
140
2.34
145
2.42
150
2.50
155
2.58
160
2.65
165
2.73
170
2.81
175
2.89
180
2.97
185
3.05
190
3.13
195
3.21
200
3

/h for 35 CMH

Voltage
Air exchange
[V]
[m
3
/h]
3.35
180
3.40
185
3.50
190
3.60
195
3.65
200
3.80
205
3.85
210
3.95
215
4.00
220

/h for 75 CMH

3
Voltage
Air exchange
[V]
[m
3
/h]
3.29
205
3.37
210
3.45
215
3.53
220
3.60
225
3.68
230
3.76
235
3.84
240
3.92
245
4.00
250