23.4 Air exchange sensor table voltage - m
There is an offset of 0.2 V due to mechanical design. The air exchange must be properly calibrated
before measuring.
Voltage
Air exchange
[V]
[m
3
/h]
0.20
0
0.30
5
0.50
10
0.65
15
0.80
20
0.85
25
0.95
30
1.05
35
1.15
40
1.20
45
1.30
50
1.35
55
23.5 Air exchange sensor table voltage - m
There is an offset of 0.2 V due to mechanical design. The air exchange must be properly calibrated
before measuring.
Voltage
Air exchange
[V]
[m
/h]
3
0.20
10
0.35
20
0.50
30
0.65
35
0.75
40
0.85
45
1.00
50
1.10
60
1.20
65
1.30
75
1.35
80
** DST P100 only
Voltage
Air exchange
[V]
[m
3
/h]
1.45
60
1.50
65
1.55
70
1.65
75
1.70
80
1.75
85
1.90
90
1.95
95
2.00
100
2.05
105
2.10
110
2.20
115
Voltage
Air exchange
[V]
[m
/h]
3
1.45
85
1.50
90
1.60
95
1.70
100
1.80
105
1.90
110
2.00
115
2.10
120
2.25
130
2.35
135
2.40
140
Voltage
Air exchange
[V]
[m
3
/h]
2.25
120
2.35
125
2.40
130
2.50
135
2.55
140
2.65
145
2.70
150
2.80
155
2.90
160
3.00
165
3.10
170
3.20
175
Voltage
Air exchange
[V]
[m
/h]
3
2.45
145
2.55
150
2.65
155
2.70
160
2.80
165
2.85
170
2.95
175
3.00
180
3.10
185
3.25
195
3.35
200
Operating and service manual
97 of 112 pages
3
/h for 35 CMH
Voltage
Air exchange
[V]
[m
3
/h]
3.35
180
3.40
185
3.50
190
3.60
195
3.65
200
3.80
205
3.85
210
3.95
215
4.00
220
3
/h for 75 CMH
Voltage
Air exchange
[V]
[m
/h]
3
3.40
205
3.50
210
3.55
215
3.65
220
3.70
225
3.75
230
3.80
235
3.90
240
3.95
245
4.00
250