American Dynamics IP SpeedDome Ultra 8 Installation Manual page 32

American dynamics speeddome ultra 8: installation guide
Hide thumbs Also See for IP SpeedDome Ultra 8:
Table of Contents

Advertisement

Installing IP SDU8 with a ROENDC End Cap
Check the level of the pipe assembly. If re-leveling is necessary, loosen the two set screws and
repeat steps a-c above.
6 Remove the housing from the packaging.
7 Cut a 30cm (12in) length of Teflon tape.
8 Apply Teflon tape to the threads at the top of the housing.
9 Route the cable from the housing through the bottom opening of the end cap and out its front
as shown in Figure 5-9.
Figure 5-9 Example of the cable routing through the End Cap assembly
Caution
Take care while you are threading the dome onto the End Cap to avoid any damage to the cables.
10 Twisting the cables to avoid tension, screw the housing onto the adapter pipe.
11 Keep turning the housing until tight.
12 Re-check the level of the dome in the two directions shown in Figure 5-8. Re-level if necessary.
13 Route the pigtail cables from the dome through the End Cap.
14 Place any excess cable into the end cap, and ensure the O-ring is in place.
15 Using a wrench for tamperproof screws, attach the cover to the End Cap
5-4
Figure 5-8 Checking the pipe assembly's levels
Figure 5-10 Attaching the End Cap cover
Installation Guide

Advertisement

Table of Contents
loading

Table of Contents