FAULT FINDING
Cause
4.1 Water supplies cut off.
4.2 Shower unit blocked.
4.3 Blockage in pipework.
4.4 Showerhead blocked.
4.5 System not capable
of supplying multiple
outlets at the same
time.
5.1 Running pressure is
excess of maximum
recommended.
6.1 Running pressure in
excess of maximum
recommended.
7.1. Pipework not flushed
out before connecting
to the unit. Internal
components damaged.
Action
4.1.1 Check water elsewhere in house and if
necessary contact local water company.
4.2.1 Inspect the filters. Clean if necessary.
4.3.1 Turn off the shower and consult a suitably
competent plumber.
4.4.1 Clean the showerhead.
4.5.1 Reduce the simultaneous demand.
4.5.2 Make sure stop or service valve is fully
open.
4.5.3 Check if there is sufficient water pressure.
5.1.1 Fit a pressure reducing valve.
6.1.1 Fit a pressure reducing valve.
7.1.1 Service valve.