Setting The Date Format - American Dynamics ADTTE Operation And Programming Manual

Using matrix switcher with adtte keyboard controller
Table of Contents

Advertisement

Display / Queuing /
Clearance
Block / Hold / Auto
Block / Hold / Manual
Dual / Hold / Instant
Dual / Sequence / Instant
Dual / Hold / Auto
Dual / Sequence / Auto
Dual / Hold / Manual
Dual / Sequence / Manual
Disarm Monitor
Enable Manual Override
Disable Manual Override
Display Arming Status
IMPORTANT!
If a dual display code [13-15] is
selected, the second (sequence) monitor is
automatically selected after the first (hold) monitor is
armed. The sequence monitor number will always
equal the hold monitor number + 1.
Note:
Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
the Keyboard on page 14.
To arm a monitor:
1. Call the monitor to be armed.
Note:
To display the current arming status, enter
0, and press Mon Arm On.
2. Select the desired arming code from Table 6.
3. Enter the command number (1-18), and press
Mon Arm On. The code letters will be displayed
for five seconds in the on-screen status line.
Note:
Selecting a monitor (1-16), and pressing Mon
Arm On. This activates the arming method
designated by using the Monitor menu (page 27).
Option for Manual Override
Any monitor assigned for instant or auto clearance
can be additionally enabled for manual override.
Note:
Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
the Keyboard on page 14.
To enable or disable manual override:
1. Call the desired armed monitor.
2. Do one of the following:
Command
17-Mon Arm On
18- Mon Arm On Disable manual override
Any monitor armed for manual clearance will display
a four-letter code acronym with "A" (acknowledge)
as its fourth or right-most code letter.
MEGAPOWER 48 / ADTTE
OPERATION AND PROGRAMMING REFERENCE GUIDE
Code
Command
BHA
11-Mon Arm On
BHM
12-Mon Arm On
DHI
13-Mon Arm On
DSI
DHA
14-Mon Arm On
DSA
15-Mon Arm On
DHM
DSM
--
16-Mon Arm On
or Mon Arm Off
--
17-Mon Arm On
--
18-Mon Arm On
--
0-Mon Arm On
Function
Enable manual override
Disarming a Monitor
Note:
Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
the Keyboard on page 14.
1. Clear all currently active alarms.
2. Select the monitor you want to disarm (1-16).
3. Press Mon Arm Off.
Note:
You can also disarm a monitor using the
arming code. Select the monitor you want to disarm,
enter 16 and press Mon Arm On.
Resetting the System
WARNING:
!
all programmed information about the
system. Before performing this task,
backup your settings using the S3
software.
To clear all previously programmed information, and
reset the system to its original default settings,
perform a system reset.
Note:
Verify that the keyboard is in programming
mode before performing this task. See Unlock/Lock
the Keyboard on page 14.
1. Enter 55 and press F2.
2. Enter 99 and press F2.
Note:
Step 2 must be performed within 3 seconds of
performing step 1 or the reset will not occur.

Setting the Date Format

Note:
This procedure may also be performed
through the menus. See Changing Time and Date
Settings on page 24.
There are three options for the on-screen date
format:
• Month-date-year (MM-DD-YY)
• Date-month-year (DD-MM-YY)
• Year-month-date (YY-MM-DD)