Summary of Contents for American Dynamics MicroPower EP AD1650B
Page 1
Matrix Switching System. The AD1650B MicroPower EP is a CCTV surveillance system for multiple video inputs, multiple video outputs, and multiple control stations. The AD1650B is capable of controlling a maximum of 128 video input sources such as cameras and a maximum of 16 video outputs such as monitors and video tape recorders. Menu-driven programming is provided on the AD1650B for most system setup operations.
Page 2
This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system. NOTE: Information furnished by SENSORMATIC is believed to be accurate and reliable.
CONTENTS DESCRIPTION... 1 System Features ... 1 SYSTEM OPERATION ... 1-1 System Keyboards ... 1-2 Keyboard Control ... 1-2 Non-Menu Programming... 1-2 Menu Programming... 1-2 System Reset... 1-3 Operating System Software Verification ... 1-3 KEYBOARD CONTROL ... 2-1 Keyboard Passcode Entry... 2-2 Logon...
Page 4
Programming Overview... A-3 Monitor Arming Code ... A-4 Alarm Arming Notes ... A-5 Arming Codes - Arm Types... A-6 On-Screen Status Line Displays ... A-8 American Dynamics Keyboards ... A-9 Computer Control ... A-10 Keyboard Auxiliary Key Functions... A-11 Page...
The AD1650B MicroPower EP Matrix Switching System is a CCTV surveillance system having multiple video inputs, multiple video outputs, and multiple control stations. The AD1650B is capable of controlling a maximum of 128 video input sources such as cameras and a maximum of 16 video outputs such as monitors and video tape recorders.
Page 6
(e.g., Pan/Tilt/Lens/Auxiliaries). Menu-Driven Setup: On-screen menus are provided for simplified AD1650B system setup and programming. The AD1650B menu display can be directed to a separate monitor or connected back to the system for display on any system monitor. Memory Retention: User-programmed data is stored in memory and is battery-backed for a minimum of five years.
This section of the manual provides an overview of the system operation and setup programming functions. System Operation ........1-2 System Keyboards .
The AD1650B Central Processing Module controls all Matrix Switching System operation and provides programming menus for AD1650B System setup. Eight 2-wire keyboard ports are provided on the AD1650B. In addition, four RS-232 ports are provided for control inputs from keyboards, external computers, or alarm interface units.
AD1650B System Reset Following initial AD1650B system installation or a major re- configuration of the switching system, it may be necessary to clear all programmed information from the AD1650B, and reset the system to factory defaults. User-programmed data is stored in memory and is battery- backed for a minimum of five years.
This section of the manual describes the standard AD1650B system video switching and control capabilities that are provided from an American Dynamics keyboard. These system operations are “monitor oriented” in that a keyboard controls only those functions associated with the monitor under control of the keyboard.
KEYBOARD CONTROL Keyboard Passcode Entry Passcode entry is a security procedure to allow only authorized personnel to operate the AD1650B system. When USER IDS is enabled (see USER IDENTIFICATION menu, page 4-28), AD1677 and AD1676B keyboards cannot access the system.
Adjustments to the on-screen display position and brightness of each monitor are made with controls located on the associated Video Output Module of the AD1650B switching bay. Refer to the Video Output Module Setup procedures in the AD1650B Switching System Installation manual, OP1650B, for these adjustments.
5. Press the AUX OFF button to deactivate a latching type auxiliary function. Note: The current state of latching type functions, such as locks or gates, may not be discernible from the keyboard. If critical, operator feedback should be provided via a monitor or other device. AD1650B...
64 separate cameras. Each camera is displayed for a set period of time (the Dwell Time). Tours are created in two ways in the AD1650B. Monitor Tours are temporary tours defined by keyboard non-menu programming, page 3-4. System Tours are defined and saved by menu programming, page 4-5.
“*” CN code, all alarms in the Wired set are cleared when this alarm is cleared. Alarmed monitors that are armed for Instant or Auto Clear are cleared automatically by the system (see Alarm Clearance, page A-4 of the Appendix). AD1650B...
Non-Menu Programming This section of the manual describes the AD1650B system non-menu programming capabilities. These setup operations are accessed from AD1678CM or AD2078 keyboards only. As a security feature, these keyboards have a keyswitch for disabling these programming functions. System Reset... 3-2 Operating System Verification...
If the “99 F2” is not entered within the 3-second period, the system does not reset. When this combination of keys is entered, the AD1650B clears and resets all user programmed functions (Tours, Salvos, Alarm Programming, Event Timers, etc.). This action resets these programmed functions to the factory default settings.
AD1650B Monitor Display Arrangement The arrangement of the titles, date, and time in the monitor on- screen display (Figure 2-1) may be changed by keyboard commands. The default arrangement is titles, date, and time displayed at the bottom of the screen.
After System Tour is called to a monitor it may be altered by the re-programming steps above. This does not permanently re-program the stored System Tour, but effectively “changes” it to a Monitor Tour. AD1650B...
Dual monitors), Queuing method (Sequence or Hold), and the Clearance method (Instant, Auto, or Manual clear). The Monitor Arming Codes available in the AD1650B are listed at the right, and are described in the Appendix, page A-4. To arm a monitor: 1.
For a Keyboard, For a Port, and System Wide. For a Keyboard - When sound is turned off at a keyboard, the AD1650B will transmit the sound character to all keyboards but a keyboard that is off will not sound the audio tone.
This section of the manual describes the AD1650B menu programming capabilities. Menu Programming... 4-2 Accessing the Menu System... 4-2 Exiting from the Menu System... 4-2 Main Selection Menu... 4-2 Cursor Positioning/Paging... 4-3 System Menus... 4-3 Set Time and Date ... 4-4 Set System Tours ...
MENU PROGRAMMING MENU PROGRAMMING All the features of the AD1650B are programmable using on- screen menus. The menus are displayed via a separate video output (labeled PROG MON) on the rear of the AD1650B. This video output may be connected to a dedicated monitor or connected back into the video switching system for display on any monitor.
AD1650B Menu Cursor Positioning/Paging The following cursor instructions apply to all menus. To position the cursor to a desired location on the menu: • Use the joystick to move the cursor to the desired selection. • Press the NEXT button until the cursor is placed at the desired selection.
ACK key. 1 - SUN 2 - MON 3 - TUE PREVIOUS MENU returns to the SYSTEM menu, page 4-3. See page 4-3 for cursor movement instructions. AD1650B 4 - WED 5 - THR 6 - FRI 7 - SAT...
AD1650B SET SYSTEM TOURS A System Tour is a programmable sequence of cameras that can be called by a user to be displayed on the called monitor, or called by Event Timers to any monitor. The SET SYSTEM TOURS menu permits programming of 64 System tours. Each tour includes 64 entries.
Page 28
2 O N 0 0 3 0 0 4 1 O F F 1 0 0 2 O F F 0 2 4 0 0 7 0 0 8 P R E V I O U S M E N U AD1650B...
Page 29
AD1650B CN (Connect Next) If a salvo or tour switching is desired at a tour entry: 1. Move the cursor to the CN column and desired entry line. 2. Press the ACK key to cycle through the CN selections. Press the NEXT key to accept the displayed selection.
• If “N” is selected, the salvo stops at this camera entry. • If “S” is selected, another System Salvo is called and this salvo stops at this entry. The PREVIOUS MENU line of the SET SYSTEM SALVOS menu returns to the SYSTEM menu, page 4-3. AD1650B...
AD1650B PROGRAMMING A SALVO To select a System Salvo for programming: 1. Position cursor to the SALVO line in the menu. 2. Enter the desired salvo number (from 1 to 16). 3. Press the ACK key. See page 4-3 for cursor movement instructions.
S E T E V E N T T I M E R S T I M E - 0 7 : 11 D AY O F W E E K P R E V I O U S M E N U AD1650B...
Page 33
AD1650B Alarm Monitor/Contact (ALM ) callup Separate Monitor/Contact Tables can be programmed to define which alarm contacts are armed for each monitor in the system (see page 4-27 for Monitor/Contact Table programming). The first table, Table 0, defines the current (active) system monitor/contact arming state.
“*” symbol. This indicates that when the associated ACN is manual Acknowledged, all alarm contacts in that Wired set are cleared. The PREVIOUS MENU line of the SET ALARM CONTACTS menu returns to the SYSTEM menu, page 4-3. 4-12 AD1650B...
AD1650B PROGRAMMING ALARM CONTACTS Alarm Contact Numbers 1 to 128, 129 to 256, 257 to 384, and 385 to 512 are defaulted to cameras 1 through 128, respectively. Dwell Times are defaulted to two seconds. To select an Alarm Contact for programming: - Move the cursor to the desired Alarm Contact Number (ACN) line of the menu (from 1 to 512).
Page 36
Display, Queuing, and Clearance methods for each monitor. Refer to the Monitor menu, page 4-16, to arm the monitors. Refer to the Appendix, pages A-3 to A-7, for further description of Alarm Programming. 4-14 AD1650B A U X 1 O N...
AD1650B MONITOR STATUS The MONITOR STATUS display provides information about the 16 monitors connected to the system. This display has two pages, with eight monitors per page. Refer to page 4-3 for menu paging instructions. M O N I T O R S TAT U S...
See the Appendix, pages A-3 to A-7, for further definition of Alarm Programming and Monitor Arming Codes. 4-16 Monitor Arming Codes Description First Monitor Arm Type DHM A* AD1650B Arm Type SSM A* SHM A* BSM A* BHM A* Second Mon Arm Type...
Page 39
AD1650B ## (Block number) - The block number field associates monitors together to form a monitor “block” for alarm callup. A monitor block may consist of any set of system monitors and need not be contiguous. When a block ARM TYPE is selected above, the cursor is moved to the Block number field and a default block number is automatically indicated.
The actual (Real) camera number is the number associated with the individual input BNC on the rear panel of each AD1650B Video Input Module. This menu has multiple pages, with eight camera numbers per page.
AD1650B TITLE The Camera TITLE menu is used to program a 16-character alphanumeric title for each camera, for inclusion in the on- screen display. C A M E R A - 0 0 0 1 T I T L E -...
The PORT menu is used to configure baud rates, data bits, parity, stop bits, and port use for each of the four RS-232 ports on the rear of the AD1650B. Note: Once the selections for a port have been made, do not change the settings (Baud, Parity, etc.) unless the...
Page 43
AD1650B ALARM - Used for an Alarm Interface Unit connection for input of alarm codes to the AD1650B. Each alarm event message sent to this port generates an output message to a serial printer via the PRINTER port (see below).
For proper keyboard numbering, verify if a port expander is used and to which port it is connected. Two-Wire Keyboards Eight ports on the rear of the AD1650B are provided for two- wire keyboards, and are separately numbered from 1 to 8 in the keyboard access menus.
Y Y Y Y Y Y Y Y ports on the rear panel of the AD1650B. Eight two-wire keyboard ports are provided. The port number on the rear panel, labeled 1 - 8, corresponds to the monitor number controlled via that port.
AD1650B KEYBOARD/CAMERA CONTROL This menu defines the Keyboard-to-Camera control access which prevents selected keyboards from controlling remote functions on selected cameras. This feature only prevents control, it does not prevent camera viewing. (Any camera that is locked from a keyboard would also be, by default, locked from that keyboard for control.)
“locked out”, it will not be viewed during the System Tour. 4-26 Y = this camera can be viewed on this monitor. N = no viewing of this camera at this monitor. AD1650B...
AD1650B MONITOR/CONTACT ACCESS The MONITOR/CONTACT ACCESS menu defines which alarm contacts are associated to each monitor in the system. Five Monitor/Contact Tables can be programmed by this menu, providing different Monitor/Contact associations. The first table, Table 0, is the current (active) system Monitor/Contact arming status.
When USER IDS is enabled, the user must have a user number and a passcode to access the system through an AD1678CM or AD2078 keyboard. See User Passcode Entry, page 1-3, for the logon and logoff procedures when USER IDS is enabled. 4-28 AD1650B...
CHANGE PARAMETERS - If enabled, the selected priority level can change system data through the menus. If Menu Access (above) is disabled for this priority level, Change Parameters is disabled and cannot be enabled. PREVIOUS MENU - Returns to the PRIORITY menu, page 4-28. 4-30 AD1650B...
Auxiliary and Preset Alarm Callups ... A-5 Wired Alarm Contact Sets ... A-5 Monitor Arming Codes - Arm Types... A-6 On-Screen Status Displays ... A-8 American Dynamics Keyboards ... A-9 Remote Computer Control of AD1650B... A-10 Keyboard Auxiliary Key Code Functions ... A-11 Appendix...
Page 54
APPENDIX AD1650B SYSTEM DEFAULTS The following are the factory default values; these are set from the System Reset function, page 1-3 or 3-2. Keyboard Control All Monitors switch to Camera 1; all Keyboards have no Monitors under their control Non-Menu Programming...
All types of alarm signals are referred to as alarm contacts by the AD1650B. Each external alarm contact is assigned an alarm contact number (ACN) at the source. A maximum of 512 alarm contacts can be programmed for response by the AD1650B.
Wired Set with a “*” CN code, when it is acknowledged all alarms in the set are cleared. Note: If the Dual alarm display method is used, call the Hold monitor to manually acknowledge an alarm. The different Arming Codes are described on page A-6 to A-7. AD1650B...
AD1650B ALARMS - ARMING NOTES Associating Alarms with Camera Salvos Each alarm contact may be associated with a camera salvo for callup when the alarm is received. Camera salvos can be defined either by the System Salvo menu, page 4-8, or by the Connect Next feature of the Alarm Contacts menu, page 4-12.
ALARMS - MONITOR ARMING CODES - ARM TYPES The following are the available Monitor Arming Codes for the AD1650B. Each is identified by the code number, in parentheses, and the ARM TYPE letter code as displayed in the Monitor menu, page 4-16.
Page 59
AD1650B BLOCK Display, HOLD Queuing (10) BHI - Multiple monitor alarm block, all armed/alarmed contacts are queued and displayed on monitors with no existing alarms. Monitors display and hold the first alarmed contacts. The alarmed contacts are removed from the queue when the alarm closure is restored.
AD1650B software). Operation The following messages appear in the monitor on-screen Status Line during normal AD1650B operation. nnF - Displayed during running a System Tour, page 2-5. The message shows the dwell time of the currently displayed camera, and the letter “F” for a tour running in Forward direction.
2 Requires appropriate On-Site Receivers 3 Wall-type transformer supplied 4 From the AD1650B Central Processing Module, via system connection 5 For rack mount models add suffix R to the model number; (5.25" H) 6 Cameras 1 - 99 and Monitors 1 - 8 only...
RS-232C protocol. As shipped, all ports are set for operation at 1200 baud with 8 data bits, 1 stop bit, and no parity. The AD1650B ports are programmed for type of use and communication parameters via the on-screen Ports menu (page 4-20).
AD1650B AUXILIARY KEY CODE FUNCTIONS F1 - Special function key: 1 F1 - Unlocks the current camera 2 F1 - Locks the current camera 99 F1 - Logoff from passcode Logon F2 - Special function key*: 1 F2 - Sets on-screen Time and Date display ON 2 F2 - Sets on-screen Time and Date display OFF 3 F2 - Sets Camera Title, Number, &...
Page 64
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 800-442-2225 FAX: (914) 624-7685 8000-0870-01 OP1650BSPB November 1994 Printed in USA...
Need help?
Do you have a question about the MicroPower EP AD1650B and is the answer not in the manual?
Questions and answers