American Dynamics ADTTE Operation And Programming Manual

American Dynamics ADTTE Operation And Programming Manual

Using matrix switcher with adtte keyboard controller
Table of Contents

Advertisement

Using MegaPower 168 Matrix Switcher with
ADTTE Keyboard Controller
Operation and Programming Reference Guide
Figure 1: MegaPower 168 (AD168) Typical Configuration
AD2088
ADTTE
Parallel Printer
Keyboard
Touch Tracker
Port (standard)
168 Inputs
AD168
Manchester
Fixed
Camera
AD High Speed
RS-422
Data Line
(standard)
SensorNet
Dome
Control Code Modules
(optional)
Code Distributor
(optional)
Outputs
1-12
PTZ
Figure 2: ADTTE Keyboard Controller
© Sensormatic 2002
MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A)
1 of 31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADTTE and is the answer not in the manual?

Questions and answers

Summary of Contents for American Dynamics ADTTE

  • Page 1 AD High Speed RS-422 Data Line (standard) SensorNet Dome Control Code Modules (optional) Code Distributor (optional) Outputs 1-12 Figure 2: ADTTE Keyboard Controller © Sensormatic 2002 MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) 1 of 31...
  • Page 2: Table Of Contents

    Changing User Settings ... 30 Changing Keyboard Priority Settings ... 30 Configuring Priority Settings ... 31 MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) About this Guide This operation and reference guide explains tasks you can perform using the ADTTE keyboard with the MegaPower 168 (AD168) Matrix Switcher.
  • Page 3: About The Megapower 168 Matrix Switcher/Controller System

    SensorNet. A parallel printer port is standard with each AD168 system to provide printed copies of operating parameters and alarm events. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) About the ADTTE Keyboard Controller The ADTTE keyboard is a video control station that is compatible with the AD168 matrix switcher/ controller systems.
  • Page 4 The Entry field shows the numbers being entered on the keypad. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) e. The Status field shows the current operating state of the system. During normal operation, “P”...
  • Page 5 Figure 4 illustrates the locations of the buttons on the ADTTE keypad. Figure 4: Keypad button locations Prog User Hold Site Salvo Last Next A. Numeric Keypad: Keys ranging from 0 to 9 that enable the user to select specific cameras, monitors, salvos, tours, presets, patterns, auxiliaries, recorders, sites, and macros.
  • Page 6: Identifying The Adtte Operating Mode

    The F1 button also is used to set the baud rate and display the firmware version information for the ADTTE. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Identifying the ADTTE Operating Mode...
  • Page 7: General User Tasks

    3. UC (User Code) appears on the LCD to indicate successful log off. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Working in Keyboard Lock Mode When the keyboard is in the Lock mode, the following AD168 tasks can be performed.
  • Page 8: Selecting Monitors

    Depending upon the camera type, you may be able to control the pan, tilt, zoom, focus, and iris settings. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Locking Cameras and Domes Cameras can be “locked” to prevent other keyboard operators from controlling their movements.
  • Page 9: Controlling Zoom And Focus

    Zoom In (tele) Zoom Out (wide) MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Adjusting Iris Settings Normally, the brightness of a picture is controlled by the camera's auto gain and the auto/manual iris functions. The Iris Control keys allow you to manually adjust the brightness or darkness of an image.
  • Page 10: Calling Presets

    Note: If the selected pattern has not been programmed, the default “Apple Peel” pattern runs. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) To repeat a pattern: 1. Call the dome that will run the pattern.
  • Page 11: Controlling Tours

    To re-start a tour in the reverse direction, press the Last key, followed by the Run key. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Controlling Auxiliary Devices An auxiliary is a relay that controls devices such as lights, door locks, and audible alarms.
  • Page 12: Acknowledging Alarms

    3. Repeat steps 1 and 2 for each alarm in the sequence until all alarms are cleared. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Acknowledging a Wired Set A wired set is a set of alarm contacts such that when any one member of the set is activated, all of the members are activated.
  • Page 13: Working In Program Mode

    Program Audio Alarms To modify the keyboard settings, see Changing ADTTE Keyboard Settings on page 19. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Unlock/Lock the Keyboard Before any programming tasks can be performed, you must first unlock the keyboard by entering the keyboard lock password.
  • Page 14: Pattern Programming

    6. When finished programming the pattern, press the Ack key to save. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Pattern Programming for Older SpeedDome Series Domes If you have older SpeedDome series domes installed at your facility, use the following procedure.
  • Page 15: Programming Monitor Tours

    6. Press the Hold or Run key to exit the tour programming mode. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Removing a Camera from a Tour 1. Press the Next key until the desired camera scene is displayed, then press the Hold key.
  • Page 16: Alarm Clearance Methods

    DIS (disarmed). Note: Monitor blocks must be defined through S³ software. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Table 6: Monitor Arming Codes Code # Display / Queuing / Clearance Single / Sequence / Instant...
  • Page 17: Resetting The System

    3. Select the desired arming code from Table 6, and enter the code number (1-16) on the numeric keypad. 4. Press Mon Arm Off to disarm the monitor. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Resetting the System WARNING: Resetting the AD168 clears all programmed information about the system.
  • Page 18: Text Display Arrangement

    5. Enter the keyboard lock password and press Lock to prevent further adjustment of the text overlay. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Detecting Camera Video Loss The AD168 system has built-in video loss detection.
  • Page 19: Audio Alarm Programming

    Enables audio alarms for all keyboard ports 45 F2 Disables audio alarms for all keyboard ports MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Changing ADTTE Keyboard Settings Use the following procedures to change settings specific to the ADTTE keyboard.
  • Page 20: Adjusting The Lcd Brightness

    Italian To change the language appearing on the LCD: 1. Enter 35, and then press Config. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) 2. Press the Next button to scroll through the language choices. 3. Press Ack when the correct language choice appears on the LCD.
  • Page 21: Working In Menu Mode

    Note: The menu functions are printed beneath the primary key function names on the ADTTE keypad appliqué. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Table 11: Multi-Function keys description Menu Function Page Left...
  • Page 22: Using The Main Selection Menu

    Enter (Shot) key. Use the joystick to move the highlight, and press the Enter (Shot) key. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Changing the Language Setting The AD168 menus can be displayed in the following languages: English, French, German, Spanish, and Portuguese.
  • Page 23: Changing System Options

    Users/Keyboard menu. The setting for User IDs does not take effect until exiting Menu mode. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Configuring Automatic Menu Call-up The Menu Callup setting identifies which video input is connected to Prog Mon video output.
  • Page 24: Changing Time And Date Settings

    Use this menu to select the date format, change the current date setting, and change the current time setting for the system. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Selecting the Date Format The Date Format setting selects the format for displaying the system date.
  • Page 25: Changing Port Settings

    Once the port is selected, continue with changing the relevant settings. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Changing the Baud Rate 1. Move the cursor to the Baud setting. 2. Press the Enter (Shot) key to display the available baud rates (300, 1200, 2400, 4800, 9600, 19.2K, or 38.4K).
  • Page 26: Changing Monitor Settings

    Aux (auxiliary) See the Appendix in the AD168 Administrator’s Manual for a listing of the Port Use Types. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Changing Monitor Settings The Monitor menu provides the ability to review and change the setup programming for each monitor.
  • Page 27: Changing Camera Settings

    Select Off to disable title display. 3. When finished making changes, press Exit (Pattern) to return to the previous menu. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Changing Camera Settings The Cameras menu is used to change settings associated with pseudo-numbering, video loss detection, camera titles, and preset titles.
  • Page 28 In addition, you can set the video loss detection mode for the camera. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) To change the camera title or video loss setting: 1. Move the cursor to the Camera number line.
  • Page 29: Configuring User Or Keyboard Settings

    Repeat steps 4b-4c to complete the title. 5. When finished making changes, press Exit (Pattern) to return to the previous menu. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Configuring User or Keyboard Settings The Users/Keyboards menu is used to set priority...
  • Page 30: Changing User Settings

    Repeat steps 5a and 5b. 6. When finished making changes, press Exit (Pattern) to return to the previous menu. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) Changing Keyboard Priority Settings If User IDs are disabled and Keyboard is selected...
  • Page 31: Configuring Priority Settings

    8 priority levels. MEGAPOWER 168 / ADTTE OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-02, REV. A) To configure a Priority Level: 1. Move the cursor to the Level menu item.

This manual is also suitable for:

168Megapower 168

Table of Contents