Xylem Bellingham + Stanley OPTi Quick Start Manual

Xylem Bellingham + Stanley OPTi Quick Start Manual

Digital handheld refractometer

Advertisement

Quick Links

Quick start guide
Installing batteries
Zero calibration
FILL the
dish with
water
Taking a reading
FILL the
dish with
sample
Changing measurement scale
Displaying the measurement temperature
Turning off
Manufacturer's details
Bellingham + Stanley, a Xylem brand
Xylem, Longfield Road, Tunbridge Wells, Kent, TN2 3EY, UK.
sales.bs.uk@xyleminc.com
www.bellinghamandstanley.com
H
O
2
hold
< 3
sec
Press &
release
or
60
sec
hold
4
sec
then
press
READ
hold
3
sec
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bellingham + Stanley OPTi and is the answer not in the manual?

Questions and answers

Summary of Contents for Xylem Bellingham + Stanley OPTi

  • Page 1 Changing measurement scale hold then < 3 press READ Displaying the measurement temperature Press & release Turning off hold Manufacturer’s details Bellingham + Stanley, a Xylem brand Xylem, Longfield Road, Tunbridge Wells, Kent, TN2 3EY, UK. sales.bs.uk@xyleminc.com www.bellinghamandstanley.com...
  • Page 2: Instrument Overview

    It is also recommended that the batteries seconds. should be removed during international transit or for long periods without use. Manufacturer’s details Bellingham + Stanley, a Xylem brand Xylem, Longfield Road, Tunbridge Wells, Kent, TN2 3EY, UK. sales.bs.uk@xyleminc.com www.bellinghamandstanley.com...
  • Page 3: Special Features Menu

    Setting up your OPTi Your OPTi has been delivered with “Brix” in scale position A ( ). For many applications this is enough to start working straight out of the box. S. A . 0 1 When first switching on, the instrument will briefly display the scale loaded to each channel.
  • Page 4: Scale List

    Scale list Index Application Scale Units Range Primary °Brix (ATC) 0–95 Primary °Brix (no TC) 0–95 Primary Refractive Index (ATC) 1.33–1.53 Primary Refractive Index (no TC) 1.33–1.53 Automotive AdBlue®/DEF (NOx reduction) % Weight / Weight 0–40 Automotive Ethylene Glycol °C Freezing Point 0 to -50 Automotive Ethylene Glycol...
  • Page 5: User Operation

    User operation Taking a reading Zero calibration Before taking a reading clean the prism surface thoroughly using a The zero calibration is essential to ensure accurate readings. A zero suitable solvent, eg water or methyl alcohol depending on the sample calibration should be carried out daily.
  • Page 6: Error Messages

    Error messages In order to achieve the maximum performance from the refractometer, it is essential that care is taken when cleaning the instrument and applying sample to the prism. Sample concentration may vary considerably from the surface to the centre of a mass whether in a beaker or on a spoon or spatula.