Note
The Operating instructions were originally written in German. Store in a safe place for future reference. Subject
to technical changes without notice. No responsibility is taken for printing or other types of errors.
Published by
© J. Schmalz GmbH, 09/19
This document is protected by copyright. J. Schmalz GmbH retains the rights established thereby. Reproduction of
the contents, in full or in part, is only permitted within the limits of the legal provisions of copyright law. Any mod-
ifications to or abridgments of the document are prohibited without explicit written agreement from
J. Schmalz GmbH.
J. Schmalz GmbH · Johannes-Schmalz-Str. 1 · 72293 Glatten, Germany · T: +49 7443 2403-0
schmalz@schmalz.de
EN-US · 30.30.01.01986 · 00 · 09/19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVE-TR-M and is the answer not in the manual?

Questions and answers

Summary of Contents for Schmalz EVE-TR-M

  • Page 1 Any mod- ifications to or abridgments of the document are prohibited without explicit written agreement from J. Schmalz GmbH. J. Schmalz GmbH · Johannes-Schmalz-Str. 1 · 72293 Glatten, Germany · T: +49 7443 2403-0 schmalz@schmalz.de EN-US · 30.30.01.01986 · 00 · 09/19...
  • Page 2: Table Of Contents

    Contents Contents 1 Important information ........................... 3 1.1 Note on Using this Document .......................  3 1.2 The technical documentation is part of the product ................ 3 1.3 Warnings in This Document........................ 3 1.4 Symbol.............................. 3 1.5 Type Plate ...............................  4 2 Fundamental Safety Instructions........................ 4 2.1 Intended Use............................
  • Page 3: Important Information

    ð Failure to follow the instructions in these Operating instructions may result in life-threatening injuries! ð Schmalz is not liable for damage or malfunctions that result from failure to heed these instructions. If you still have questions after reading the technical documentation, contact Schmalz-service at: www.schmalz.com/services...
  • Page 4: Type Plate

    The vacuum pump is built in accordance with the latest standards of technology and is delivered in a safe operat- ing condition. The Schmalz vacuum pump is intended to convey, evacuate and compress gases. Neutral gases in accordance with EN 983 are approved as evacuation media. Neutral gases include air, nitrogen and inert gases (e.g.
  • Page 5: Changes To The Vacuum Generator

    4 Do not extract liquids or bulk materials, e.g. granulates. 2.3  Changes to the Vacuum Generator Schmalz assumes no liability for consequences of modifications over which it has no control: 1. The vacuum generator must be operated only in its original condition as delivered.
  • Page 6: General Parameters

    4  Technical Data 4.1  General Parameters For exact electrical and pneumatic data: see the type plate and/or data sheet. Parameter Symbol Value Permissible ambient temperature ° C +5 to +40 Permissible gas temperature ° C +5 to +40 4.2  Materials of Pump Parts that Come into Contact with the Gas Component Material Pump head...
  • Page 7: Diagrams

    1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing. 2. Damage caused by defective packaging or occurring in transit must be reported immediately to the carrier and J. Schmalz GmbH. 6  Installation 6.1  Installation Instructions...
  • Page 8: Mounting

    For safe installation, the following instructions must be observed: 1. Install the pump only using only the operating parameters and under the conditions described in the “Techni- cal Data” chapter. 2. Use only the connections, mounting holes and attachment materials that have been provided. 3.
  • Page 9: Pneumatically Connecting The Pump

    To ensure the required level of damping, the additional circuitry must be installed as per the following electrical plan and the components defined within it. C1: Capacitor ≥ 2200 µF / UN = 12 V ≥ 1000 µF / UN = 24 V 6.4 ...
  • Page 10: Operation

    Excess pressures and their associated hazards can be avoided by using a bypass line with a pressure-limiting valve between the pressure and suction side of the pump. Additional information is available from the Schmalz specialist consultants (for their phone numbers, see the first page).
  • Page 11: Maintenance

    9  Warranty IMPORTANT! A warranty claim can only be accepted by Schmalz if the pump has been installed and used in accordance with its corresponding operating instructions. In the case of inappropriate handling or use of force, any warranty and lia- bility claims shall be void.
  • Page 12 Membranes, valve plates or seals are worn Malfunction cannot be corrected! If you cannot identify any of the listed causes, send the pump to the Schmalz customer service (see the first page for the address). 1. Disconnect the power supply and remove the pump 2.
  • Page 13: Ec Conformity

    The underlying requirements of Directive 2006/42/EC as per Appendix I (“General Principles”) are applied and complied with. EC Declaration of Incorporation The manufacturer Schmalz confirms that the product vacuum pump EVE-TR described in these operating instruc- tions fulfills the following applicable EC directives: 2006/42/EC...
  • Page 14: Declaration Of Decontamination

    Schmalz to repair the pump. 4 Copy this page. Enter the pump model, serial number and the conveyed medium in the form below and send the signed form to the Schmalz customer service together with the flushed and cleaned pump. J. Schmalz GmbH Customer service Johannes-Schmalz-Str.