Definition of the Danger Zone ................... 8 Emissions .......................... 9 1.10 Personal Protective Equipment ..................9 Product Description ................... 10 Schmalz Blower Box components ...................10 Type plate ........................10 Technical Data ....................11 Delivery, Packaging and Transport ..............12 Delivery ..........................12 Packaging ........................12...
Consequence ► Remedial action Caution This warning informs the user of a risk that could result in damage to property if it is not avoided. ATTENTION Type and source of danger Consequence ► Remedial action 4 | EN www.schmalz.com 30.30.01.00159/01...
Explanation of the mandatory symbols used in the operating and maintenance instructions. Mandatory Description Mandatory Description symbols symbols Wear protective glasses Wear safety shoes Wear protective gloves Disconnect mains plug Adhere to the operating instructions 30.30.01.00159/01 www.schmalz.com EN | 5...
► These operating and maintenance instructions are specific to the items included in delivery from Schmalz. They do not take into account any modifications to the system made by the customer, which are strictly prohibited. ►...
The above-mentioned vacuum pumps as well as the Schmalz Blower SB-M and SB-L blower types are designed for installation by the customer (see instructions in section 5). The blowers of the Schmalz Blower SB-V blower type are installed in the Schmalz Blower Box ex works (due to the connection of the external fan required).
(accessibility to the fastening screws for the hood, and working space for removing the hood). The Schmalz Blower Box SBB must only be set up horizontally. Consoles for attaching the Schmalz Blower Box horizontally to e.g. crane columns are available as accessories.
Wear protective glasses. 1.10 Personal Protective Equipment When operating the Schmalz Blower Box always wear suitable protective equipment: 1. Safety shoes (in accordance with EN 20345 safety class S1 or better) 2. Sturdy work gloves (in accordance with EN 388 safety category 2133 or better) 3.
The type plate is firmly attached to the exterior of the Schmalz Blower Box. The type plate contains the following information: 10 | EN www.schmalz.com...
TECHNICAL DATA Technical Data Schmalz Blower Box Length [mm] Width [mm] Height [mm] Weight [kg]* 27.7 * without vacuum generator, may vary depending on the design. For the vacuum pump EVE-TR 40 (50Hz) the silencer box enables a reduction in the noise emissions to 65 dB(A).
4.2 Packaging Depending on the scope of the shipment, the Schmalz Blower Box is transported either in a cardboard box or wooden crate, or on a pallet. The packaging material must be disposed of in accordance with country- specific laws and guidelines.
Page 13
DELIVERY, PACKAGING AND TRANSPORT CAUTION Load suspension outside the center of gravity May cause damage to the screw union between pump and metal tray. ► Sudden and incorrect lifting should be avoided. 30.30.01.00159/01 www.schmalz.com EN | 13...
Schmalz Blower Box. 2. Position the base plate at the intended installation location. Important: If the Schmalz Blower Box is used, the vacuum pump may only be installed in a horizontal position. The base plate must be securely connected to the support with 4 screws.
Page 15
Place the cover on the base plate from above. Attach onto the base plate using the 4 hex bolts (with flange, size M6). Vacuum pump in the Schmalz Blower Box is ready for operation! 30.30.01.00159/01 www.schmalz.com EN | 15...
Schmalz Blower Box. 2. Position the base plate at the intended installation location. Important: If the Schmalz Blower Box is used, the blower may only be installed in a horizontal position. The base plate must be securely connected to the support with 4 screws.
Page 17
1. Place the cover carefully on the base plate from above. 2. Attach to the base plate using 4 hex nuts (M6) and washers. Blower in the Schmalz Blower Box is ready for operation! For connection set for exhaust air hose option: 1.
5.3 Installing on a blower console 5.3.1 Vacuum pump Installation on the blower console (accessories) using 4 hex bolts (M10) and counter nuts. 5.3.2 Vacuum blower Installation as for vacuum pump. See also mounting instructions for blower console 30.30.01.00881. 18 | EN www.schmalz.com 30.30.01.00159/01...
Before the start of operations, check that the vacuum generator rotation direction corresponds with that in the operating instructions provided separately. Ensure that the Schmalz Blower Box is securely screwed to the supporting surface. When operating the Schmalz Blower Box with a blower:...
Schmalz Blower Box and pump operating and maintenance instructions. 6.2 Description of Operation The Schmalz Blower Box allows the noise emissions caused by the vacuum generator to be reduced to a minimum. The cover must be properly closed during the operation of the vacuum generator for this.
MAINTENANCE 7 Maintenance The vacuum generator must be disconnected from the circuit prior to working on the Schmalz Blower Box. As the vacuum generator emits heat, a cooling time of 60 minutes must be observed. If necessary, the temperature should be checked with a thermometer (max. 40°C).
Page 22
In short, easy-to-understand videos we explain the comprehensive functions offered by our products. Take a look, it’s worth it! www.schmalz.com/gewusst-wie Further services ranging from consultation to training can be found at www.schmalz.com/services J. Schmalz GmbH Aacher Strasse 29 D-72293 Glatten Tel. +49 (0)7443 2403-0 Fax +49 (0)7443 2403-259 schmalz@schmalz.de...
Need help?
Do you have a question about the Blower Box SBB and is the answer not in the manual?
Questions and answers