ERROR-09 TH/UNTH MOTOR TIMEOUT

(TH/UNTH MOTOR)

Description:
Malfunction of threading or unthreading operation was detected.
Detecting conditions:
1) When condition of the function cam sensors are not shifted more than four
2) When the mode shift of the function cam sensors are abnormal state.
Sub error message:
None
Possible causes:
. Threading motor trouble
. Threading motor drive circuit (SV-194 board) trouble
. Threading mechanism trouble
. Function cam sensor trouble
Protecting operations:
Enters the protection mode during tape threading/unthreading.
Stops the tape transport and enters the rest state in cases except the above.
ERROR-10 HUMID

(HUMID)

Description:
Dew condensation was detected.
Detecting condition:
When the condensation sensor detects dew condensation continuously for about
two seconds.
Sub error message:
None
Possible causes:
. Actual dew detection (When the operating environment rapidly changes from
. Condensation sensor trouble
. Dew input port (IC401 on SV-194 board) trouble
Protecting operations:
Stops the drum rotation or prohibits the rotation of drum.
Prohibits the cleaning roller operation.
Stops the tape transport and enters the rest state in the unthread end state when
the tape is threaded in states other than PLAY and REC mode.
Prohibits the tape threading.
n
When this sensor detects due condensation once, the error message will be
displayed for about 40 minutes even if a dry state is detected later.